225kV金属陶瓷X射线管设计与研制
详细信息    查看官网全文
摘要
射线探伤作为五大常规无损检测方法,在工业上有着非常广泛的应用。相应地,随着工业CT蓬勃发展,用于数字成像的X射线管也有很大的市场需求,其中拥有双焦点的金属陶瓷射线成像管最为常用。本文在设计的基本结构基础上,对X射线管的电极参数进行了优化仿真设计,并对超高耐压管的设计进行了分析讨论。最后成功制备出了225kV的1.0mm和5.0mm的双焦点成像管,测试结果表明具有很好的穿透率和较好的分辨率。
X-raynondestructive detects exhibit many advantages and attractive market prospects in industrial application. Correspondingly, as a core component the X-ray tubes have a great market needs, and dual focus X-ray tube based on metal and ceramics structure is the most commonly X-ray tube. We successfully developed a 225 kV dual X-ray tube with focus of 1.0 mm and 5.0 mm respectively after optimized the electrodeparameters and analyzed the mechanism of breakdown from ultra high voltage and the safeguard against ultrahigh voltage breakdown. The prepared X-ray tube presents high penetration performance and nice resolution.
引文
[1]刘斌,王学斌,张晓梅,曾春辉,陈华北.300kV超高压波纹陶瓷X射线管优化设计[J].无损检测.2015(37):92-97.
    [2]于开坤,张冠军,田杰,郑楠,黄学增,马新沛,李广新,山纳康,小林信一.不同掺杂对可加工陶瓷二次电子发射机沿面闪络特性的影响[J].电工技术学报.2011(1):32-36.
    [3]雷杨俊,肖定全,唐兵华.氧化铝陶瓷表面二次电子发射特性及测量[J].硅酸盐学报.2006(06):713-716.
    [4]王灿,X射线管超高耐压性能研究[D].四川:电子科技大学,2016.