为更快速准确检测超低碳钢中的碳含量,分别对影响直读光谱仪分析超低碳钢含量的因素制样方式、氩气流量与压力进行了研究,确定了最优条件,并将分析结果与红外碳硫仪分析的结果进行了对比,结果表明直读光谱仪分析超低碳是一种具有分析速度快、准确度与精度高的方法。
The factors including sample making and argon gas flow and pressure are discussed that influence carbon content analysis in ultra-low carbon steel by direct-reading spectrometry to detect more accurately and quickly carbon content in ultra-low carbon steel.The results shows that the direct-reading spectrometry is satisfactory based on optimal analysis condition with high precision and accuracy by compared with infrared absorption method.