摘要
本文在理论上分析了超声导波在土壤中的传播特性,计算出L(0,1)模态可以用来对接地体进行检测。同时建立实验系统,对直径12 mm,长2 m的接地体,在土壤、含石土壤、湿润土壤等不同环境下进行检测,实验结果表明,超声导波可以适用于干燥土壤环境下输电线路接地装置缺陷的检测,具有一定的工程实用价值。
Propagation characteristics of ultrasonic guided wave of grounding device for electric transmission line were studied. It was indicated that longitudinal mode L(0,1) could be used in the inspection of bolt embedded in soil.At the same time, the experiments with bolts 12 mm in diameter, 2 m in length embedded in different soil such as soil, soil of containing stone and wet soil detected using ultrasonic guided waves were carried out. It was shown that Ultrasonic Guided-wave can been used for the inspection of construction flow of bolt embedded in dry soils, this method is practically valuable.
引文
[1]杨滔,彭敏放,洪海涛等.接地网状态快速检测方法[C]中国高等学校电力系统及其自动化专业第二十六届学术年会暨中国电机工程学会电力系统专业委员会2010年年会.上海:上海电力学院电力与自动化工程学院,2010.
    [2]王炯耿,林群,罗宏建等.接地网扁钢超声导波检测实验研究,Research on Ultrasonic Guided Wave Test of Flat Steel for Grounding Grid[J].浙江电力,2012,4,4-7。
    [3]ROSE J L.固体中的超声波[M].何存富,吴斌,王秀彦,译.北京:科学出版社,2004.ROSE J L.Ultrasonic waves insoild media[M].HE Cun-fu,WU Bin,WANG Xiu-yan translator.Beijing:Science Press,2004.
    [4]王秀彦,王智,焦敬品,等.超声导波在管中传播的理论分析与试验研究[J].机械工程学报,2004,40(1):11–16.WANG Xiu-yan,WANG Zhi,JIAO Jing-pin,et al.Theoretical and experimental studies of ultrasonic guided waves propagation in pipes[J].Chinese Journal of Mechanical Engineering,2004,40(1):11–16.
    [5]Rose.J.L The upcoming revoltion in ultrasonic guided waves[C]Proceedings of the SPIE-The international Society for Optical Engineering.New York:American Institute of Physics,2011,7983
    [6]GB50065《交流电气装置的接地设计规范》[S],北京:中国标准出版社,2011