非接触式方向传感器测量发电机定子局部放电的研究
详细信息    本馆镜像全文|  推荐本文 |  |   获取CNKI官网全文
摘要
根据现场的要求,本文研制出一种非接触式空气电容传感器,它具有频带宽、绝缘
     性能好、灵敏度高的特点,可以在高压端测量高频放电脉冲,可以代替各种接触式传感
     器在发电机高压母线端进行在线局部放电监测。这种传感器不与发电机母线直接接触,
     容易安装,安全性好,易于被用户 所接受。
     通过大量的试验研究,开发出了由这种传感器组成的方向传感器系统,给出了在
     100 M S/s 采样率下方向传感器判别放电脉冲的判据,并开发出判别软件。此方向传感
     器系统可以有效地识别外部干扰脉冲和局部放电脉冲 。 研制出一种 基于这种传感器的发
     电机定子局部放电监测系统。此系统可在实验室正确运行,可以对放电进行监测、从干
     扰中提取局部放电脉冲、统计分析放电类型并绘制出统计谱图。
Based on the requirement of electrica l power plants, we designed a new
     type of sensors for stator winding Partial Discharge measurement online. The
     sensors are of good insulation, high sensitivity, easy installation on site, and
     good safety, suitable for on - site application.
     We developed a se t of directional sensors with the analyzing software for
     eliminating pulse interference from the transformer side based on our developed
     non - contact type PD sensors. We also developed a PD on - line detecting system
     for stator windings of generators, which c onsists of a set of non - contact type
     directional sensors, digital system, and software. The detecting system can
     monitor PD online, reject noises, analyze PD faults, and show the finger prints
     of the detected PD.
引文
[1] G.C.Stone, Partial Discharge - Part VII: Partial Techni ques for Measuring PD
     in Operating Equipment, IEEE Electrical Insulation Magazine, 1991, 7(4): 9 - 16
     [2] 苏鹏声,汪小明,曹海翔,等,大型发电机定子绕组局部放电在线监测
     系统的研究,电工电能新技术, 2000 ( 2 ): 49 - 52
     [3] R.Thucker , H.G . kranz., Requirements of Automated PD Diagnosis System for
     Fault Identific ation in Noisy Conditions, IEEE Transactions on Dielectric and Electric
     Insulation, 1995, 2 (4): 544 - 556
     [4] 杨莉,全玉生,周跃锋,等,大型发电机定子绕组故障放电的特性和识
     别,电工电能新技术, 1999 ( 2 ): 23 - 27
     [5] M.Kurtz, J.F.Lyles, Generator Insulation Diagnostic Testing, IEEE
     Transactions on PAS, 1979, 5(9/10): 1596 - 1603
     [6] M.Kurtz , J.F.Lyles, G.C.Stone, Application of Partial Discharge Testing to
     Hydro Generator Maintenance, IEEE Transactions on PAS, 1984, 103 (8) :2148 - 2156
     [7] 王昌长,李福祺,电力设备的在线监测与故障诊断,清华大学电机工程
     与应用电子技术系, 1996, 5
     [8] 刘立生,邱阿瑞,高压电 机局部放电在线监测方法,电工电能新技术,
     1999 ( 3 ), 23 - 27
     [9] F.T. Emery , B.N. Lenderking, R.D. Couch , Turbine Generator on - line
     Diagnostics U sing RF Monitoring, IEEE Transactions on PAS, 1981, 100 (12):
     4974 - 4982
     [10] 黄成军 , 郁维庸 , 局部放电在线监测技术及其在电机中的应用 , 大电机技
     术, 2000(3), 24 - 31
     [11] P.Gruen ewald, J.Weidner, Possibilities and Experience with off - and on - line
     Diagnose is of Turbine Generator Stator Winding Insulations, Proceedings of the 35
     International Conference on Large High Voltage Electric Systems, Paris, 1994,
     8.28~9.03: part l ,11 - 206
     [12] G.C.Stone, H.G.Sedding, In - service Evaluation of Motor and Generator
     Stator Winding Using Partial Discharge Tests, IEEE trans. on IAS, 1995, 31(2): 299 - 303
     [13] G.C. Stone, H.G. Sedding, M.J. Costello , Application of Partial Discharge
     Testing to Motor s and Generator Stator Winding Maintenance, IEEE trans. on IAS, 1996,
     32(2): 459 - 464 51
    
    
    
    
    
    
     华北电力大学(北京)硕士学位论文
     [14] K. Itoh, Y. Kaneda, K. Kimura, etc, New Noise Rejection Techniques on
     Pulse - by - Pulse Basis for on - line Partial Discharge Measurement of Turbine Generators,
     IEEE trans. on Energy Con - version, 1996, 11(3): 585 - 592
     [15] Q.Su, A New Partial Discharge Detector for On - line Insulation Condition
     Monitoring of Generators, 10th International Symposium on High Voltage Engineering,
     Montreal, Quebec, Canada, 1998, 8.25~8.29: 291 - 294
     [16] 吴广宁 , 吴欣延 , 谢恒 , 等,大型发电机局部放电在线监测仪的研究,仪
     器仪表学报 , 1998, 19(1)
     [17] 李武峰 , 大型发电机定子局部放电在线监测技术的研究 , (硕士学位论
     文 ) ,北京,华北电力大学(北京)电力工程系, 2002
     [18] 王好,大电机定子局放在线监测抗干扰技术的研究 , (硕士学位论文 ),
     北京,华北电力大学(北京)电力工程系, 2003
     [19] 万伟江,超高频法在发电机局部放电中的应用 , (硕士学位论文 ) ,北京,
     华北电力大学(北京)电力工程系, 2004
     [20] G.C.S tone, Partial Discharge Part XXV: Calibration of PD Measurements for
     Motor and Generator Windings - Why It Can . t Be Done, IEEE Transactions on Energy
     Conversion , 1998, 1 4 (1) , 9 - 1 2
     [21] H.Zhu, V.Green, M.Sasic, Increased Sensitivity of Capacitive Couplers fo r
     In - Service PD Measurement in Rotating Machines, IEEE Transactions on Energy
     Conversion, 1999, 4(4), 6 - 11
     [22] 彭湃,大型发电机定子绝缘局部放电故障的模拟试验与模式识别 , (硕
     士学位论文 ) ,北京,华北电力大学(北京) 电力工程系 , 2000
     [23] 谈克雄,姜建国,王镇远,等,用人工神经网络对电机绝缘模型放电的
     识别,清华大学学报(自然科学版 ), 1996, 36,46 - 51
    
     52

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号