药物洗脱支架对血管重构和内皮功能影响的实验和临床研究
详细信息    本馆镜像全文|  推荐本文 |  |   获取CNKI官网全文
摘要
第一部分药物洗脱支架对冠状动脉血管重构影响的实验研究
     目的:评价金属裸支架(BMS)、雷帕霉素洗脱支架(SES)和新型壳聚糖/肝素逐层自组装(C/HLBL)涂层支架植入猪冠状动脉后,对支架及其边缘节段血管重构的影响。
     方法:采用小型猪为实验动物,在猪冠状动脉内随机植入BMS(BMS组)、SES(SES组)和C/HLBL涂层支架(LBL组)。分别在支架植入后即刻和3-6个月随访时对各组支架植入血管行血管内超声(IVUS)检查和定量分析测定。
     结果:16头小型猪32支靶血管(BMS组9支,SES组11支,LBL组12支)完成了术后即刻和随访时的血管内超声检查。三组支架的支架节段在术后即刻的各项IVUS参数在组间均没有显著性差异。术后3-6个月随访时,三组支架节段的血管面积、中层和斑块面积以及支架面积在组间仍无显著性差异,但SES组和LBL组的管腔面积显著大于BMS组(SES组6.34±0.89 mm2比BMS组4.31±1.28 mm2,P=0.001:LBL组5.43±0.88 mm2比BMS组4.31±1.28 mm2.,P=0.029)。与术后即刻相比,BMS组在随访时发现显著的内膜增生,支架内管腔面积显著减小(4.31±1.28 mm2,比6.97±0.73 mm2,P<0.001);LBL组在随访时也存在一定程度的管腔缩小(5.43±0.88 mm2比6.90±0.64 mm2,P<0.001),但其内膜增生程度显著低于BMS组(新生内膜面积1.40±0.96 mm2比2.69±1.58mm2,P=0.032):SES组在随访时支架梁表面的内膜覆盖不明显,管腔面积较术后即刻无显著变化(6.34±0.89 mm2比6.72±0.79 mm2,P:0.305),三支架组在随访时的血管面积、中层和斑块面积以及支架面积较术后即刻均未发生显著变化。各组在IVUS随访中均未发现晚期支架贴壁不良(ISA)现象。三组支架的支架近端和远端边缘5mm内血管节段在术后即刻和术后3-6个月随访时的血管面积、中层和斑块面积和管腔面积在组间和组内均没有显著性差异。
     结论:BMS植入猪正常冠状动脉后3-6个月随访时发生显著的内膜增生,而SES的内膜增生程度低,支架梁表面内皮覆盖不明显,C/HLBL涂层支架的内膜增生程度则介于BMS和SES之间;BMS、SES和C/HLBL涂层支架植入猪正常冠状动脉后,支架外周和支架边缘节段血管均没有出现明显的血管重构。
     第二部分药物洗脱支架对冠状动脉内皮功能影响的实验研究
     目的:评价金属裸支架(BMS)、雷帕霉素洗脱支架(SES)和新型壳聚糖/肝素逐层自组装(C/HLBL)涂层支架植入猪冠状动脉后,对支架邻近节段心外膜冠状动脉内皮功能的影响。
     方法:采用小型猪为实验动物,在猪冠状动脉内随机植入BMS (BMS组)、SES(SES组)和C/HLBL涂层支架(LBL组)。分别在支架植入后即刻和3-6个月随访时于支架植入靶血管内注入乙酰胆碱(先后采用6ug、60ug和600ug共3种剂量)和硝酸甘油(200ug)行内皮依赖性和非依赖性血管舒缩反应试验,通过定量冠状动脉造影分析测定支架邻近节段心外膜冠状动脉在药物注入前后的内径变化。
     结果:18头小型猪41支靶血管(BMS组12支,SES组13支,LBL组16支)完成了完整的内皮依赖性和非依赖性血管舒缩反应试验。在冠脉内注入乙酰胆碱后,SES组支架近端和远端无支架节段(NSRS)表现为随剂量递增而加重的血管收缩反应,且以支架远端NSRS更为显著(随乙酰胆碱剂量递增,远端直径变化百分数分别为-14.1±6.2%,-23.5±13.7%和-52.8±22.5%;近端直径变化百分数分别为-5.3±2.7%,-5.9±3.1%,-7.3±3.0%)。与BMS组(随乙酰胆碱剂量递增,远端直径变化百分数分别为-4.2±2.6%,-5.4±2.9%和-5.7±3.0%;近端直径变化百分数分别为-3.3±2.1%,-4.6±2.7%和-4.9±3.5%)相比,LBL组支架近端和远端NSRS的内皮依赖性血管舒缩功能没有显著性差异(随乙酰胆碱剂量递增,远端直径变化百分数分别为-3.2±2.1%,-3.8±1.9%和-4.4±2.9%;近端直径变化百分数分别为-2.8±2.2%,-4.9±1.9%和-5.2±2.1%)。各组支架近端和远端NSRS对硝酸甘油的非内皮依赖性血管舒张反应没有显著性差异。
     结论:与BMS相比,SES植入猪冠状动脉后可导致支架邻近节段NSRS的血管舒缩功能受损,且以支架远端为著,提示局部内皮功能障碍;新型C/HLBL涂层支架植入猪冠状动脉后不会影响支架邻近节段血管的内皮功能,其内皮依赖性血管舒缩反应与BMS相比没有显著性差异。
     第三部分药物洗脱支架植入术后晚期支架贴壁不良的血管内超声研究
     目的:通过血管内超声(IVUS)对药物洗脱支架(DES)植入后发生晚期支架贴壁不良(ISA)的患者进行研究,评价ISA与血管重构的关系,同时对发生晚期ISA的患者进行长期随访,探讨晚期ISA对临床预后的影响。
     方法:从复旦大学附属中山医院心导管室血管内超声检查数据库中,选择连续15例DES植入后发生晚期ISA的患者。同时,在IVUS数据库中根据靶血管、糖尿病、DES类型、参照血管外弹力膜(EEM)横截面面积以2:1配对的方式选择同期30例未发生晚期ISA的患者作为对照组。分别对晚期ISA组患者支架内的ISA节段和相邻无ISA节段、以及对照组无ISA患者的术后随访期的IVUS影像行定量分析测定。并对所有15例晚期ISA患者进行2年以上的临床随访。
     结果:15例在随访时被检出晚期ISA患者中,2例(13%)ISA位于支架的边缘节段(支架边缘的5mm内),13例(87%)位于支架的中段体部。ISA最大面积和角度分别为5.3±2.2 mm2和163±67°。与相邻的无ISA节段相比,发生晚期ISA节段的最大EEM面积和血管重构指数均显著增加(分别为24.1±3.3比20.1±3.1mm2, P=0.002和1.6±0.2比1.3±0.2,P=0.001)。而两组的支架内管腔面积、斑块和中层面积均没有显著性差异(P>0.05)。晚期ISA患者与对照组无ISA患者相比,各项基线临床和造影特征、以及IVUS随访时支架近端和远端参照节段EEM面积、管腔面积以及支架节段的支架面积均无显著性差异(P>0.05);但晚期ISA组的最大EEM面积和血管重构指数均显著大于对照组(分别为24.1±3.3比18.8±4.2mm2, P=0.002和1.6±0.2比1.3±0.2,P=0.001)。两组的支架内管腔面积、斑块和中层面积均没有显著性差异(P>0.05)。对15例晚期ISA患者进行了2年以上的临床随访,平均随访时间为(34±5)个月,3例(20%)患者发生了急性ST段抬高型心肌梗死,其中1例抢救无效死亡。3例患者发生心肌梗死后均接受了急诊冠脉造影,证实为极晚期支架血栓形成。这3例极晚期支架血栓分别发生在支架植入术后的第29,31和32个月,即复查造影和IVUS发现晚期ISA后的第20,23和23个月。
     结论:DES植入后发生的晚期ISA与支架植入节段异常的扩张性血管重构有关;DES植入后随访期检出的晚期ISA可能导致DES极晚期支架内血栓的易感性增加。
Part I:Experimental evaluation of coronary remodeling after drug-eluting stent implantation
     Objective:To evaluate the response of the coronary vessel wall to implantation of the bare metal stent (BMS), sirolimus-eluting stent (SES), and chitosan-heperin layer-by-layer self assembly (C/H LBL) coating stent by using serial intravascular ultrasound.
     Methods:The BMS, SES and C/H LBL stents were randomly implanted in the miniature pigs'coronary arteries. Serial intravascular ultrasound (IVUS) was performed immediately after the stent implantation and at 3-6 months follow-up. Quantitative IVUS analysis was then performed in the stent segments,5 mm coronary segments immediately proximal and distal to the stent.
     Results:Serial IVUS was available for 9 BMSs (BMS group),11 SESs (SES group), and 12 C/H LBL stents (LBL group). At follow-up, significantly larger lumen (SES group 6.34±0.89 mm2 vs. BMS group 4.31±1.28 mm2, P=0.001; LBL goup 5.43±0.88 mm2 vs. BMS group 4.31±1.28 mm2, P=0.029; respectively) and lower neointimal hyperplasia areas (SES group 0.28±0.35 mm2 vs. BMS group 2.69±1.58 mm2, P=0.002; LBL goup 1.40±0.96 mm2 vs. BMS group 2.69±1.58 mm2, P= 0.032; respectively) were seen in the SES group and LBL group compared with the BMS group (by ANOVA, P< 0.001). There was no significant difference between 3 groups in either the vessel area or the media& plaque behind stent area change (all P>0.05) from after the procedure to late follow-up. For both the proximal and the distal edges, the vessel and lumen areas were also comparable among 3 groups (all P>0.05). No late incomplete stent apposition was observed in all 3 groups.
     Conclusion:The marked reduction in neointimal hyperplasia with SES and C/H LBL stent is not associated with abnormal vascular response or edge effects at follow-up IVUS.
     Part II:Experimental evaluation of coronary endothelial function associated with drug-eluting stent, and chitosan-heperin layer-by-layer self assembly coating stent
     Objective:To evaluate the coronary endothelial function following percutatneous implantation of the bare metal stent (BMS), sirolimus-eluting stent (SES), and chitosan-heperin layer-by-layer self assembly (C/H LBL) coating stent at follow-up.
     Methods:The BMS, SES and C/H LBL stents were randomly implanted in the miniature pigs'coronary arteries. Endothelial function was estimated by incremental acetylcholine (Ach) (6,60,600 ug) and nitroglycerin (200 ug) infusions into the coronary ostium at 3-6 months follow-up. The vascular response was quantitatively measured in the 10-mm segments proximal and distal to the stent.
     Results:The coronary vasomotor response was tested for 12 BMSs (BMS group),13 SESs (SES group), and 16 C/H LBL stents (LBL group). In the SES group, more intense vasoconstriction to incremental doses of Ach was observed at follow-up compared with the BMS goup, and was more prominent in the distal segments (-14.1±6.2%,-23.5±13.7%,-52.8±22.5%, respecitively to incremental doses of Ach) than the proximal segments (-5.3±2.7%,-5.9±3.1%,-7.3±3.0%, respecitively to incremental doses of Ach). Endothelial function associated with the C/H LBL stent (distal:-3.2±2.1%,-3.8±1.9%,-4.4±2.9%; proximal:-2.8±2.2%,-4.9±1.9%,-5.2±2.1%, respecitively to incremental doses of Ach) and BMS (distal:-4.2±2.6%,-5.4±2.9%,-5.7±3.0%; proximal:-3.3±2.1%,-4.6±2.7%,-4.9±3.5%, respecitively to incremental doses of Ach) was preserved at follow-up compared with the SES. There is no significant difference in endothelium-dependent vasomothion between LBL group and BMS goup. Endothelium-independent vasodilation to nitrate did not differ significantly among the study groups.
     Conclusion:SES implantation may induce significant impairment of the endothelium-dependent vasomotor function in the adjacent portion of the stent segment, while the endothelial function associated with C/H LBL stent can be well preserved.
     Part III:Intravascular ultrasonic evaluation in patients with late incomplete stent apposition after drug-eluting stent implantation
     Objective:To evaluate the coronary morphological characteristics and present the clinical outcomes of a more than 2-year follow-up in patients with late incomplete stent apposition (ISA) after drug-eluting stent implantation.
     Methods:From the IVUS database of our institute,15 consecutive patients who underwent DES implantation into de novo lesions and had documented ISA at follow-up by IVUS were identified. The ISA group was compared with a matched control group of patients (n=30) who had no evidence of ISA at follow-up. Clinical follow-up was available up to 41 months after DES implantation and up to 33 months after identification of ISA.
     Results:Of the 15 documented late ISA after DES implantation, two located at the edge (within 5 mm from stent margin) while 13 in the body of the stent. The maximum area and arc of ISA measured 5.3±2.2 mm2 and 163±67°, respectively. In patients with late ISA, the maximum external elastic membrane (EEM) area of stent segment with ISA was significantly larger than the adjacent stent segment without ISA (24.1±3.3 vs.20.1±3.1 mm2, P= 0.002), while stent area, plaque plus media (P&M) area and intrastent lumen area were comparable (P>0.05). Compared to the matched control cohort without ISA at follow-up, the maximum EEM area was also significantly larger in the late ISA group (24.1±3.3 vs.18.8±4.2 mm2, P< 0.001), while the areas of reference EEM and lumen, stent, P&M behind the stent, intimal hyperplasia and intrastent lumen were all comparable between the two groups (P>0.05). Over a mean follow-up of(34±5) months (range 24-41 months),3 of the 15 patients (20.0%) suffered from ST elevated myocardial infarction with one death. Very late stent thrombosis in the area with late ISA was demonstrated by the emergency coronary angiography in all 3 patients.
     Conclusion:Late ISA revealed at follow-up after DES implantation was associated with significant positive vessel remodeling. With regard to the clinical sequelae, late ISA may be associated with a high incidence of very late stent thrombosis.
引文
1. Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346:1773-1780.
    2. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349:1315-1323.
    3. Stone GW, Ellis SG, Cox DA, Hermiller J, O' Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004; 350:221-231.
    4. Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (randomized study with the sirolimus-eluting velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial. Circulation 2002; 106:798-803.
    5. Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, et al. Randomized study to assess the effectiveness of slow-and moderaterelease polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003; 108:788-794.
    6. Stone GW, Ellis SG, Cannon L, Mann JT, Greenberg JD, Spriggs D, et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease:a randomized controlled trial. JAMA 2005; 294:1215-1223.
    7. Marroquin OC, Selzer F, Mulukutla SR, Williams DO, Vlachos HA, Wilensky RL, et al. A comparison of bare-metal and drug-eluting stents for off-label indications. N Engl J Med.2008; 358(4):342-352.
    8. Zhang F, Ge J, Qian J, Fan B, Wang Q, Ge L, et al. Sirolimus-eluting stents in real-world patients with ST-segment elevation acute myocardial infarction. Int Heart J 2007; 48(3):303-311.
    9. Wenaweser P, Daemen J, Zwahlen M, van Domburg R, Juni P, Vaina S, et al. Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice.4-year results from a large 2-institutional cohort study. J Am Coll Cardiol.2008; 52(14):1134-1140.
    10. Kastrati A, Mehilli J, Pache J, Kaiser C, Valgimigli M, Kelbaek H, et al. Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents. N Engl J Med.2007; 356(10):1030-1039.
    11. Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, et al. Safety and efficacy of sirolimus-and paclitaxel-eluting coronary stents. N Engl J Med.2007; 356(10):998-1008.
    12. Pfisterer M, Brunner-La Rocca HP, Buser PT, Rickenbacher P, Hunziker P, Mueller C, et al. Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents:an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol.2006; 48(12):2584-2591.
    13. Ong AT, McFadden EP, Regar E, de Jaegere PP, van Domburg RT, Serruys PW. Late angiographic stent thrombosis (LAST) events with drug-eluting stents. J Am Coll Cardiol.2005; 45(12):2088-2092.
    14. Park DW, Park SW, Park KH, Lee BK, Kim YH, Lee CW, et al. Frequency of and risk factors for stent thrombosis after drug-eluting stent implantation during long-term follow-up. Am J Cardiol.2006; 98(3):352-356.
    15. Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA.2005; 293(17):2126-2130.
    16. Meng S, Liu Z, Shen L, Guo Z, Chou LL, Zhong W, et al. The effect of a layer-by-layer chitosan-heparin coating on the endothelialization and coagulation properties of a coronary stent system. Biomaterials.2009; 30(12):2276-2283.
    17. Ge JB, Shen L, Zhong W, Yang W, Tian WJ, Tang JL, et al. The Preclinical Assessment of a Novel Biodegradable Rapid Prohealing Polymer with Sirolimus-Eluting Coating Stent in a Porcine Model. Circulation.2010; 122(2): e331.
    18. Mintz GS, Shah VM, Weissman NJ. Regional remodeling as the cause of late stent malapposition. Circulation.2003; 107(21):2660-2663.
    19. Nakamura M, Kataoka T, Honda Y, Bonneau HN, Hibi K, Kitamura K, et al. Late incomplete stent apposition and focal vessel expansion after bare metal stenting. Am J Cardiol.2003; 92(10):1217-1219.
    20. Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, et al. Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J.2010; 31(10):1172-1180.
    21. Pendyala LK, Yin X, Li J, Chen JP, Chronos N, Hou D. The first-generation drug-eluting stents and coronary endothelial dysfunction. JACC Cardiovasc Interv.2009; 2(12):1169-1177.
    22. Muhlestein JB. Endothelial dysfunction associated with drug-eluting stents what, where, when, and how? J Am Coll Cardiol.2008; 51(22):2139-2140.
    23. Kern MJ. Persistent endothelial dysfunction after drug-eluting stents:another continuing cost of reducing restenosis. JACC Cardiovasc Interv.2008;1(1):72-73.
    24. Lerman A, Eeckhout E. Coronary endothelial dysfunction following sirolimus-eluting stent placement:should we worry about it? Eur Heart J.2006; 27(2):125-126.
    25. Serry R, Penny WF. Endothelial dysfunction after sirolimus-eluting stent placement. J Am Coll Cardiol.2005; 46(2):237-238.
    26. Lerman A, Zeiher AM. Endothelial function:cardiac events. Circulation.2005; 111(3):363-368.
    27. Suwaidi JA, Hamasaki S, Higano ST, Nishimura RA, Holmes DR Jr, Lerman A. Long-term follow-up of patients with mild coronary artery disease and endothelial dysfunction. Circulation.2000; 101(9):948-954.
    28. Schachinger V, Britten MB, Zeiher AM. Prognostic impact of coronary vasodilator dysfunction on adverse long-term outcome of coronary heart disease. Circulation.2000; 101(16):1899-1906.
    29. Akcakoyun M, Kargin R, Tanalp AC, Pala S, Ozveren O, Akcay M, et al. Predictive value of noninvasively determined endothelial dysfunction for long-term cardiovascular events and restenosis in patients undergoing coronary stent implantation:a prospective study. Coron Artery Dis.2008; 19(5):337-343.
    30. Celik T, Iyisoy A, Kursaklioglu H, Celik M. The forgotten player of in-stent restenosis:endothelial dysfunction. Int J Cardiol.2008; 126(3):443-444.
    31. Kitta Y, Nakamura T, Kodama Y, Takano H, Umetani K, Fujioka D, et al. Endothelial vasomotor dysfunction in the brachial artery is associated with late in-stent coronary restenosis. J Am Coll Cardiol.2005; 46(4):648-655.
    1. Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346:1773-1780.
    2. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349:1315-1323.
    3. Stone GW, Ellis SG, Cox DA, Hermiller J, O' Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004; 350:221-231.
    4. Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (randomized study with the sirolimus-eluting velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial. Circulation 2002; 106:798-803.
    5. Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, et al. Randomized study to assess the effectiveness of slow-and moderaterelease polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003; 108:788-794.
    6. Stone GW, Ellis SG, Cannon L, Mann JT, Greenberg JD, Spriggs D, et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease:a randomized controlled trial. JAMA 2005; 294:1215-1223.
    7. Marroquin OC, Selzer F, Mulukutla SR, Williams DO, Vlachos HA, Wilensky RL, et al. A comparison of bare-metal and drug-eluting stents for off-label indications. N Engl J Med.2008; 358(4):342-352.
    8. Zhang F, Ge J, Qian J, Fan B, Wang Q, Ge L, et al. Sirolimus-eluting stents in real-world patients with ST-segment elevation acute myocardial infarction. Int Heart J 2007; 48:303-311.
    9. Ako J, Morino Y, Honda Y, Hassan A, Sonoda S, Yock PG, et al. Late incomplete stent apposition after sirolimus-eluting stent implantation:a serial intravascular ultrasound analysis. J Am Coll Cardiol.2005; 46(6):1002-1005.
    10. Mintz G, Weissman NJ, Dawkins K. Frequency, predictors, and clinical outcomes of late-acquired incomplete stent apposition in patients treated with Taxus stents a volumetric intravascular ultrasound meta-analysis from the TAXUS IV, V, and VI trials. J Am Coll Cardiol 2006; 47 Suppl B:26B.
    11. Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK, et al. Late stent malapposition after drug-eluting stent implantation:an intravascular ultrasound analysis with long-term follow-up. Circulation.2006; 113(3):414-419.
    12. Jimenez-Quevedo P, Sabate M, Angiolillo DJ, Costa MA, Alfonso F, Gomez-Hospital JA, et al. Vascular effects of sirolimus-eluting versus bare-metal stents in diabetic patients:three-dimensional ultrasound results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial. J Am Coll Cardiol.2006; 47(11): 2172-2179.
    13. Weissman NJ, Ellis SG, Grube E, Dawkins KD, Greenberg JD, Mann T, et al. Effect of the polymer-based, paclitaxel-eluting TAXUS Express stent on vascular tissue responses:a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials. Eur Heart J.2007; 28(13):1574-1582.
    14. Hoffmann R, Morice MC, Moses JW, Fitzgerald PJ, Mauri L, Breithardt G, et al. Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events:intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials. Heart.2008; 94(3):322-328.
    15. van der Hoeven BL, Liem SS, Jukema JW, Suraphakdee N, Putter H, Dijkstra J, et al. Sirolimus-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction:9-month angiographic and intravascular ultrasound results and 12-month clinical outcome results from the MISSION! Intervention Study. J Am Coll Cardiol.2008; 51(6):618-626.
    16. Sanchez-Recalde A, Moreno R, Barreales L, Rivero F, Galeote G, Jimenez-Valero S, et al. Risk of late-acquired incomplete stent apposition after drug-eluting stent versus bare-metal stent. A meta-analysis from 12 randomized trials. J Invasive Cardiol.2008; 20(8):417-422.
    17. Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, et al. Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J.2010; 31(10):1172-1180.
    18. Chechi T, Vecchio S, Lilli A, Giuliani G, Spaziani G, Baldereschi G, et al. Mechanisms of late stent malapposition after primary stenting in ST-elevation myocardial infarction:a subanalysis of the selection trial. J Interv Cardiol.2009; 22(3):201-206.
    19. van der Hoeven BL, Liem SS, Dijkstra J, Bergheanu SC, Putter H, Antoni ML, et al. Stent malapposition after sirolimus-eluting and bare-metal stent implantation in patients with ST-segment elevation myocardial infarction:acute and 9-month intravascular ultrasound results of the MISSION! intervention study. JACC Cardiovasc Interv.2008; 1(2):192-201.
    20. Maehara A, Mintz GS, Lansky AJ, Witzenbichler B, Guagliumi G, Brodie B, et al. Volumetric intravascular ultrasound analysis of Paclitaxel-eluting and bare metal stents in acute myocardial infarction:the harmonizing outcomes with revascularization and stents in acute myocardial infarction intravascular ultrasound substudy. Circulation.2009; 120(19):1875-1882.
    21. Guo N, Maehara A, Mintz GS, He Y, Xu K, Wu X, et al. Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myocardial infarction:an intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial. Circulation.2010; 122(11):1077-1084.
    22. Ueno K, Kawamura A, Mintz GS, Weissman NJ, Jinzaki M, Okabe T, et al. Progression of late stent malapposition beyond 2 years after sirolimus-eluting stent implantation. JACC Cardiovasc Interv.2009; 2(12):1288-1289.
    23. Watanabe Y, Asano R, Hata N, Inoue K, Takamisawa I, Seki A, et al. Late stent malapposition with marked positive vascular remodeling observed only at the site of drug-eluting stents after multivessel coronary stenting. Heart Vessels.2009; 24(4):308-332.
    24. Zhang F, Qian JY, Ge JB. Late stent malapposition and marked positive vessel remodeling after sirolimus-eluting coronary stent implantation. Chin Med J (Engl).2006; 119(4):349-350.
    25. Qian J, Zhang F, Wu H, Fan B, Ge L, Ge J. Comparison of intravascular ultrasonic imaging with versus without incomplete stent apposition at follow-up after drug-eluting stent implantation. Int J Cardiovasc Imaging.2008; 24(2): 133-139.
    26. Colombo A, Latib A. Late incomplete stent apposition after drug-eluting stent implantation:a true risk factor or "an innocent bystander"? Heart.2008; 94(3): 253-254.
    27. Miyazawa A, Tsujino I, Ako J, Shimada Y, Courtney BK, Sakurai R, et al. Characterization of late incomplete stent apposition:a comparison among bare-metal stents, intracoronary radiation and sirolimus-eluting stents. J Invasive Cardiol.2007; 19(12):515-518.
    28. Hur SH, Ako J, Honda Y, Sudhir K, Fitzgerald PJ. Late-acquired incomplete stent apposition:morphologic characterization. Cardiovasc Revasc Med.2009; 10(4): 236-246.
    29. de la Torre Hernandez JM. Late acquired incomplete stent apposition:incidence, mechanisms and clinical implications. EuroIntervention.2009; 5 Suppl D: Dl 12-20.
    30. Bose D, von Birgelen C, Erbel R. Intravascular ultrasound for the evaluation of therapies targeting coronary atherosclerosis. J Am Coll Cardiol.2007; 49(9): 925-932.
    31. Mintz GS, Weissman NJ. Intravascular ultrasound in the drug-eluting stent era. J Am Coll Cardiol.2006; 48(3):421-429.
    32. Weissman NJ, Koglin J, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, et al. Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation:a serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial. J Am Coll Cardiol.2005; 45(8):1201-1205.
    33. Stone GW, Ellis SG, Cox DA, Hermiller J, O' Shaughnessy C, Mann JT, et al. One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent:the TAXUS-IV trial. Circulation.2004; 109(16):1942-1947.
    34. Sousa JE, Costa MA, Sousa AG, Abizaid AC, Seixas AC, Abizaid AS, et al. Two-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries. Circulation.2003; 107(3): 381-383.
    35. Sakurai R, Hongo Y, Yamasaki M, Honda Y, Bonneau HN, Yock PG, et al. Detailed intravascular ultrasound analysis of Zotarolimus-eluting phosphorylcholine-coated cobalt-chromium alloy stent in de novo coronary lesions (results from the ENDEAVOR Ⅱ trial). Am J Cardiol.2007; 100(5): 818-823.
    36. Miyazawa A, Ako J, Hongo Y, Hur SH, Tsujino I, Courtney BK, et al. Comparison of vascular response to zotarolimus-eluting stent versus sirolimus-eluting stent:intravascular ultrasound results from ENDEAVOR III. Am Heart J.2008; 155(1):108-113.
    37. Waseda K, Miyazawa A, Ako J, Hasegawa T, Tsujino I, Sakurai R, et al. Intravascular ultrasound results from the ENDEAVOR IV trial:randomized comparison between zotarolimus-and paclitaxel-eluting stents in patients with coronary artery disease. JACC Cardiovasc Interv.2009; 2(8):779-784.
    38. Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, et al. Incomplete neointimal coverage of sirolimus-eluting stents:angioscopic findings. J Am Coll Cardiol.2006; 47(10):2108-2111.
    39. Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, et al. Pathology of drug-eluting stents in humans:delayed healing and late thrombotic risk. J Am Coll Cardiol.2006; 48(1):193-202.
    40. Meng S, Liu Z, Shen L, Guo Z, Chou LL, Zhong W, et al. The effect of a layer-by-layer chitosan-heparin coating on the endothelialization and coagulation properties of a coronary stent system. Biomaterials.2009; 30(12):2276-2283.
    41. Ge JB, Shen L, Zhong W, Yang W, Tian WJ, Tang JL, et al. The Preclinical Assessment of a Novel Biodegradable Rapid Prohealing Polymer with Sirolimus-Eluting Coating Stent in a Porcine Model. Circulation.2010; 122(2): e331.
    42. Degertekin M, Regar E, Tanabe K, Lemos P, Lee CH, Smits P, et al. Evaluation of coronary remodeling after sirolimus-eluting stent implantation by serial three-dimensional intravascular ultrasound. Am J Cardiol.2003; 91(9): 1046-1050.
    43. Shimohama T, Ako J, Yamasaki M, Otake H, Tsujino I, Hasegawa T, et al. SPIRIT III JAPAN versus SPIRIT Ⅲ USA:a comparative intravascular ultrasound analysis of the everolimus-eluting stent. Am J Cardiol.2010; 106(1): 13-17.
    44. Tanabe K, Serruys PW, Degertekin M, Guagliumi G, Grube E, Chan C, et al. Chronic arterial responses to polymer-controlled paclitaxel-eluting stents: comparison with bare metal stents by serial intravascular ultrasound analyses: data from the randomized TAXUS-Ⅱ trial. Circulation.2004; 109(2):196-200.
    45. Shah VM, Mintz GS, Apple S, Weissman NJ. Background incidence of late malapposition after bare-metal stent implantation. Circulation.2002; 106(14): 1753-1755.
    46. Mintz GS, Weissman NJ, Pappas C, Waksman R. Positive remodeling, regression of in-stent neointimal hyperplasia, and late stent malapposition in the absence of brachytherapy. Circulation.2000; 102(16):E111.
    47. Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM, et al. Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation.2004; 109(7):881-886.
    48. Schwartz RS, Huber KC, Murphy JG, Edwards WD, Camrud AR, Vlietstra RE, et al. Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. J Am Coll Cardiol.1992; 19:267-274.
    49. Karas SP, Gravanis MB, Santoian EC, Robinson KA, Anderberg KA, King SB. Coronary intimal proliferation after balloon injury and stenting in swine:an animal model of restenosis. J Am Coll Cardiol.1992; 20:467-474.
    50. Muller DWM, Ellis SG, Topol EJ. Experimental model of coronary artery restenosis. J Am Coll Cardiol.1992; 19:418-432.
    51. Hoffmann R, Mintz GS, Dussaillant GR, Popma JJ, Pichard AD, Satler LF, et al. Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. Circulation.1996; 94(6):1247-1254.
    52. Weissman NJ, Wilensky RL, Tanguay JF, Bartorelli AL, Moses J, Williams DO, et al. Extent and distribution of in-stent intimal hyperplasia and edge effect in a non-radiation stent population. Am J Cardiol.2001; 88(3):248-252.
    53. Mudra H, Regar E, Klauss V, Werner F, Henneke KH, Sbarouni E, et al. Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents. In-stent neointimal proliferation without significant reference segment response. Circulation.1997; 95(2):363-370.
    54. Waksman R, Lansky AJ. Images in cardiovascular radiation medicine. Edge restenosis post gamma radiation. Cardiovasc Radiat Med.1999; 1(2):169.
    55. Albiero R, Adamian M, Kobayashi N, Amato A, Vaghetti M, Di Mario C, et al. Short-and intermediate-term results of (32)P radioactive beta-emitting stent implantation in patients with coronary artery disease:The Milan Dose-Response Study. Circulation.2000; 101(1):18-26.
    56. Albiero R, Nishida T, Adamian M, Amato A, Vaghetti M, Corvaja N, et al. Edge restenosis after implantation of high activity (32)P radioactive beta-emitting stents. Circulation.2000; 101(21):2454-2457.
    57. Serruys PW, Kay IP. I like the candy, I hate the wrapper:the (32)P radioactive stent. Circulation.2000; 101(1):3-7.
    58. Degertekin M, Serruys PW, Foley DP, Tanabe K, Regar E, Vos J, et al. Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up. Circulation.2002; 106(13):1610-1613.
    59. Sakurai R, Ako J, Morino Y, Sonoda S, Kaneda H, Terashima M, et al. Predictors of edge stenosis following sirolimus-eluting stent deployment (a quantitative intravascular ultrasound analysis from the SIRIUS trial). Am J Cardiol.2005; 96(9):1251-1253.
    60. Serruys PW, Degertekin M, Tanabe K, Russell ME, Guagliumi G, Webb J, et al. Vascular responses at proximal and distal edges of paclitaxel-eluting stents:serial intravascular ultrasound analysis from the TAXUS II trial. Circulation.2004; 109(5):627-633.
    1. Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346:1773-1780.
    2. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349:1315-1323.
    3. Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004; 350:221-231.
    4. Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (randomized study with the sirolimus-eluting velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial. Circulation 2002; 106:798-803.
    5. Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, et al. Randomized study to assess the effectiveness of slow-and moderaterelease polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003; 108:788-794.
    6. Stone GW, Ellis SG, Cannon L, Mann JT, Greenberg JD, Spriggs D, et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease:a randomized controlled trial. JAMA 2005; 294:1215-1223.
    7. Marroquin OC, Selzer F, Mulukutla SR, Williams DO, Vlachos HA, Wilensky RL, et al. A comparison of bare-metal and drug-eluting stents for off-label indications. N Engl J Med.2008; 358(4):342-352.
    8. Zhang F, Ge J, Qian J, Fan B, Wang Q, Ge L, et al. Sirolimus-eluting stents in real-world patients with ST-segment elevation acute myocardial infarction. Int Heart J 2007; 48:303-311.
    9. Camenzind E, Steg PG, Wijns W. Stent thrombosis late after implantation of first-generation drug-eluting stents:a cause for concern. Circulation.2007; 115(11):1440-1455.
    10. Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, et al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:data from a large two-institutional cohort study. Lancet.2007; 369(9562):667-678.
    11. Kerner A, Gruberg L, Kapeliovich M, Grenadier E. Late stent thrombosis after implantation of a sirolimus-eluting stent. Catheter Cardiovasc Interv.2003; 60: 505-508.
    12. Cheneau E, Pichard AD, Stabile E, Waksman R. Asymptomatic late stent thrombosis after sirolimus stent implantation. Cardiovasc Radiat Med.2004; 5: 57-58.
    13. McFadden EP, Stabile E, Regar E, Cheneau E, Ong AT, Kinnaird T, et al. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet.2004; 364:1519-1521.
    14. Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, et al. Incidence, predictors and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA.2005; 293:2126-2130.
    15. Jensen LO, Maeng M, Kaltoft A, Thayssen P, Hansen HH, Bottcher M, et al. Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions. J Am Coll Cardiol.2007; 50(5):463-470.
    16. Bavry AA, Kumbhani DJ, Helton TJ, Borek PP, Mood GR, Bhatt DL. Late thrombosis of drug-eluting stents:a meta-analysis of randomized clinical trials. Am J Med.2006; 119(12):1056-1061.
    17. Finn AV, Nakazawa G, Joner M, Kolodgie FD, Mont EK, Gold HK, et al. Vascular responses to drug eluting stents:importance of delayed healing. Arterioscler Thromb Vase Biol.2007; 27(7):1500-1510.
    18. Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent:should we be cautious? Circulation.2004; 109:701-705.
    19. Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, et al. Pathology of drug-eluting stents in humans:delayed healing and late thrombotic risk. J Am Coll Cardiol.2006; 48:193-202.
    20. Togni M, Windecker S, Cocchia R, Wenaweser P, Cook S, Billinger M, et al. Sirolimus-eluting stents associated with paradoxic coronary vasoconstriction. J Am Coll Cardiol.2005; 46(2):231-236.
    21. Hofma SH, van der Giessen WJ, van Dalen BM, Lemos PA, McFadden EP, Sianos G, et al. Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation. Eur Heart J.2006; 27(2):166-170.
    22. Maekawa K, Kawamoto K, Fuke S, Yoshioka R, Saito H, Sato T, et al. Severe endothelial dysfunction after sirolimus-eluting stent implantation. Circulation. 2006; 113(23):e850-e851.
    23. Togni M, Raber L, Cocchia R, Wenaweser P, Cook S, Windecker S, et al. Local vascular dysfunction after coronary paclitaxel-eluting stent implantation. Int J Cardiol.2007; 120(2):212-220.
    24. Shin DI, Kim PJ, Seung KB, Kim DB, Kim MJ, Chang K, et al. Drug-eluting stent implantation could be associated with long-term coronary endothelial dysfunction. Int Heart J.2007; 48(5):553-567.
    25. Fuke S, Maekawa K, Kawamoto K, Saito H, Sato T, Hioka T, et al. Impaired endothelial vasomotor function after sirolimus-eluting stent implantation. Circ J. 2007; 71(2):220-225.
    26. Obata JE, Kitta Y, Takano H, Kodama Y, Nakamura T, Mende A, et al. Sirolimus-eluting stent implantation aggravates endothelial vasomotor dysfunction in the infarct-related coronary artery in patients with acute myocardial infarction. J Am Coll Cardiol.2007; 50(14):1305-1309.
    27. Kim JW, Suh SY, Choi CU, Na JO, Kim EJ, Rha SW, et al. Six-month comparison of coronary endothelial dysfunction associated with sirolimus-eluting stent versus Paclitaxel-eluting stent. JACC Cardiovasc Interv.2008; 1(1):65-71.
    28. Hamilos M, Sarma J, Ostojic M, Cuisset T, Sarno G, Melikian N, et al. Interference of drug-eluting stents with endothelium-dependent coronary vasomotion:evidence for device-specific responses. Circ Cardiovasc Interv.2008; 1(3):193-200.
    29. Shin DI, Seung KB, Kim PJ, Chang K, Choi JK, Jeon DS, et al. Long-term coronary endothelial function after zotarolimus-eluting stent implantation. A 9 month comparison between zotarolimus-eluting and sirolimus-eluting stents.Int Heart J.2008; 49(6):639-652.
    30. Hamilos MI, Ostojic M, Beleslin B, Sagic D, Mangovski L, Stojkovic S, et al. Differential effects of drug-eluting stents on local endothelium-dependent coronary vasomotion. J Am Coll Cardiol.2008; 51(22):2123-2129.
    31. Kim JW, Seo HS, Park JH, Na JO, Choi CU, Lim HE, et al. A prospective, randomized,6-month comparison of the coronary vasomotor response associated with a zotarolimus-versus a sirolimus-eluting stent:differential recovery of coronary endothelial dysfunction.J Am Coll Cardiol.2009; 53(18):1653-1659.
    32. Horigome M, Kumazaki S, Hattori N, Kasai H, Horigome M, Aizawa K, et al. Noninvasive evaluation of coronary endothelial function following sirolimus-eluting stent implantation by using positron emission tomography. Cardiology.2009; 114(3):157-163.
    33. Obata JE, Nakamura T, Kitta Y, Kodama Y, Sano K, Kawabata K, et al. Treatment of acute myocardial infarction with sirolimus-eluting stents results in chronic endothelial dysfunction in the infarct-related coronary artery. Circ Cardiovasc Interv.2009; 2(5):384-391.
    34. Ito S, Nakasuka K, Morimoto K, Inomata M, Yoshida T, Tamai N, et al. Angiographic and clinical characteristics of patients with acetylcholine-induced coronary vasospasm on follow-up coronary angiography following drug-eluting stent implantation. J Invasive Cardiol.2011; 23(2):57-64.
    35. Hamasaki S, Tei C. Effect of coronary endothelial function on outcomes in patients undergoing percutaneous coronary intervention. J Cardiol.2011 Mar 11. [Epub ahead of print]
    36. Lerman A, Zeiher AM. Endothelial function:cardiac events. Circulation.2005; 111(3):363-368.
    37. Suwaidi JA, Hamasaki S, Higano ST, Nishimura RA, Holmes DR Jr, Lerman A. Long-term follow-up of patients with mild coronary artery disease and endothelial dysfunction. Circulation.2000; 101(9):948-954.
    38. Schachinger V, Britten MB, Zeiher AM. Prognostic impact of coronary vasodilator dysfunction on adverse long-term outcome of coronary heart disease. Circulation.2000; 101(16):1899-1906.
    39. Akcakoyun M, Kargin R, Tanalp AC, Pala S, Ozveren O, Akcay M, et al. Predictive value of noninvasively determined endothelial dysfunction for long-term cardiovascular events and restenosis in patients undergoing coronary stent implantation:a prospective study. Coron Artery Dis.2008; 19(5):337-343.
    40. Celik T, Iyisoy A, Kursaklioglu H, Celik M. The forgotten player of in-stent restenosis:endothelial dysfunction. Int J Cardiol.2008; 126(3):443-444.
    41. Kitta Y, Nakamura T, Kodama Y, Takano H, Umetani K, Fujioka D, et al. Endothelial vasomotor dysfunction in the brachial artery is associated with late in-stent coronary restenosis. J Am Coll Cardiol.2005; 46(4):648-655.
    42. Meng S, Liu Z, Shen L, Guo Z, Chou LL, Zhong W, et al. The effect of a layer-by-layer chitosan-heparin coating on the endothelialization and coagulation properties of a coronary stent system. Biomaterials.2009; 30(12):2276-2283.
    43. Ge JB, Shen L, Zhong W, Yang W, Tian WJ, Tang JL, et al. The Preclinical Assessment of a Novel Biodegradable Rapid Prohealing Polymer with Sirolimus-Eluting Coating Stent in a Porcine Model. Circulation.2010; 122(2): e331.
    44. Gossl M, Rosol M, Malyar NM, Fitzpatrick LA, Beighley PE, Zamir M, et al. Functional anatomy and hemodynamic characteristics of vasa vasorum in the walls of porcine coronary arteries. Anat Rec ADiscov Mol Cell Evol Biol.2003; 272(2):526-537.
    45. Long C, Cook LG, Wu GY, Mitchell BM. Removal of FKBP12/12.6 from endothelial ryanodine receptors leads to an intracellular calcium leak and endothelial dysfunction. Arterioscler Thromb Vase Biol.2007; 27(7):1580-1586.
    46. Takeda Y, Miyamori I, Furukawa K, Inaba S, Mabuchi H. Mechanisms of FK 506-induced hypertension in the rat. Hypertension.1999; 33(1):130-136.
    47. Jabs A, Gobel S, Wenzel P, Kleschyov AL, Hortmann M, Oelze M, et al. Sirolimus-induced vascular dysfunction. Increased mitochondrial and nicotinamide adenosine dinucleotide phosphate oxidase-dependent superoxide production and decreased vascular nitric oxide formation. J Am Coll Cardiol. 2008; 51(22):2130-2138.
    48. Shinke T, Geva S, Pendyala L, Jabara R, Li J, Chen JP, et al. Low-dose paclitaxel elution by novel bioerodible sol-gel coating on stents inhibits neointima with low toxicity in porcine coronary arteries. Int J Cardiol.2009; 135(1):93-101.
    49. Pendyala L, Jabara R, Shinke T, Chronos N, Robinson K, Li J, et al. Drug-eluting stents:present and future. Cardiovasc Hematol Agents Med Chem.2008; 6(2): 105-115.
    50. Pendyala LK, Li J, Shinke T, Geva S, Yin X, Chen JP, et al. Endothelium-dependent vasomotor dysfunction in pig coronary arteries with Paclitaxel-eluting stents is associated with inflammation and oxidative stress. JACC Cardiovasc Interv.2009; 2(3):253-262.
    1. Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346:1773-1780.
    2. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349:1315-1323.
    3. Stone GW, Ellis SG, Cox DA, Hermiller J, O' Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004; 350:221-231.
    4. Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (randomized study with the sirolimus-eluting velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial. Circulation 2002; 106:798-803.
    5. Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, et al. Randomized study to assess the effectiveness of slow-and moderaterelease polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003; 108:788-794.
    6. Stone GW, Ellis SG, Cannon L, Mann JT, Greenberg JD, Spriggs D, et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease:a randomized controlled trial. JAMA2005;294:1215-1223.
    7. Marroquin OC, Selzer F, Mulukutla SR, Williams DO, Vlachos HA, Wilensky RL, et al. A comparison of bare-metal and drug-eluting stents for off-label indications. N Engl J Med.2008; 358(4):342-52.
    8. Zhang F, Ge J, Qian J, Fan B, Wang Q, Ge L, et al. Sirolimus-eluting stents in real-world patients with ST-segment elevation acute myocardial infarction. Int Heart J 2007; 48:303-311.
    9. Ako J, Morino Y, Honda Y, Hassan A, Sonoda S, Yock PG, et al. Late incomplete stent apposition after sirolimus-eluting stent implantation:a serial intravascular ultrasound analysis. J Am Coll Cardiol.2005; 46(6):1002-1005.
    10. Mintz G, Weissman NJ, Dawkins K. Frequency, predictors, and clinical outcomes of late-acquired incomplete stent apposition in patients treated with Taxus stents a volumetric intravascular ultrasound meta-analysis from the TAXUS IV, V, and VI trials. J Am Coll Cardiol 2006; 47 Suppl B:26B.
    11. Hong MK, Mintz GS, Lee CW, Park DW, Park KM, Lee BK, et al. Late stent malapposition after drug-eluting stent implantation:an intravascular ultrasound analysis with long-term follow-up. Circulation.2006; 113(3):414-419.
    12. Jimenez-Quevedo P, Sabate M, Angiolillo DJ, Costa MA, Alfonso F, Gomez-Hospital JA, et al. Vascular effects of sirolimus-eluting versus bare-metal stents in diabetic patients:three-dimensional ultrasound results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial. J Am Coll Cardiol.2006; 47(11): 2172-2179.
    13. Weissman NJ, Ellis SG, Grube E, Dawkins KD, Greenberg JD, Mann T, et al. Effect of the polymer-based, paclitaxel-eluting TAXUS Express stent on vascular tissue responses:a volumetric intravascular ultrasound integrated analysis from the TAXUS IV, V, and VI trials. Eur Heart J.2007; 28(13):1574-1582.
    14. Hoffmann R, Morice MC, Moses JW, Fitzgerald PJ, Mauri L, Breithardt G, et al. Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events:intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials. Heart.2008; 94(3):322-328.
    15. van der Hoeven BL, Liem SS, Jukema JW, Suraphakdee N, Putter H, Dijkstra J, et al. Sirolimus-eluting stents versus bare-metal stents in patients with ST-segment elevation myocardial infarction:9-month angiographic and intravascular ultrasound results and 12-month clinical outcome results from the MISSION! Intervention Study. J Am Coll Cardiol.2008; 51(6):618-626.
    16. Sanchez-Recalde A, Moreno R, Barreales L, Rivero F, Galeote G, Jimenez-Valero S, et al. Risk of late-acquired incomplete stent apposition after drug-eluting stent versus bare-metal stent. A meta-analysis from 12 randomized trials. J Invasive Cardiol.2008; 20(8):417-422.
    17. Hassan AK, Bergheanu SC, Stijnen T, van der Hoeven BL, Snoep JD, Plevier JW, et al. Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. Eur Heart J.2010; 31(10):1172-1180.
    18. Chechi T, Vecchio S, Lilli A, Giuliani G, Spaziani G, Baldereschi G, et al. Mechanisms of late stent malapposition after primary stenting in ST-elevation myocardial infarction:a subanalysis of the selection trial. J Interv Cardiol.2009; 22(3):201-206.
    19. van der Hoeven BL, Liem SS, Dijkstra J, Bergheanu SC, Putter H, Antoni ML, et al. Stent malapposition after sirolimus-eluting and bare-metal stent implantation in patients with ST-segment elevation myocardial infarction:acute and 9-month intravascular ultrasound results of the MISSION! intervention study. JACC Cardiovasc Interv.2008; 1(2):192-201.
    20. Maehara A, Mintz GS, Lansky AJ, Witzenbichler B, Guagliumi G, Brodie B, et al. Volumetric intravascular ultrasound analysis of Paclitaxel-eluting and bare metal stents in acute myocardial infarction:the harmonizing outcomes with revascularization and stents in acute myocardial infarction intravascular ultrasound substudy. Circulation.2009; 120(19):1875-1882.
    21. Guo N, Maehara A, Mintz GS, He Y, Xu K, Wu X, et al. Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myocardial infarction:an intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial. Circulation.2010; 122(11):1077-1084.
    22. Kimura M, Mintz GS, Carlier S, Takebayashi H, Fujii K, Sano K, et al. Outcome after acute incomplete sirolimus-eluting stent apposition as assessed by serial intravascular ultrasound. Am J Cardiol.2006; 98(4):436-442.
    23. Shah VM, Mintz GS, Apple S, Weissman NJ. Background incidence of late malapposition after bare-metal stent implantation. Circulation.2002; 106(14): 1753-1755.
    24. Mintz GS, Weissman NJ, Pappas C, Waksman R. Positive remodeling, regression of in-stent neointimal hyperplasia, and late stent malapposition in the absence of brachytherapy. Circulation.2000; 102(16):E111.
    25. Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM, et al. Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation.2004; 109(7):881-886.
    26. Mintz GS, Shah VM, Weissman NJ. Regional remodeling as the cause of late stent malapposition. Circulation.2003; 107(21):2660-2663.
    27. Nakamura M, Kataoka T, Honda Y, Bonneau HN, Hibi K, Kitamura K, et al. Late incomplete stent apposition and focal vessel expansion after bare metal stenting. Am J Cardiol.2003; 92(10):1217-1219.
    28. Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, et al. American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol.2001; 37(5): 1478-1492.
    29. Okura H, Lee DP, Lo S, Yeung AC, Honda Y, Waksman R, et al. Late incomplete apposition with excessive remodeling of the stented coronary artery following intravascular brachytherapy. Am J Cardiol.2003; 92(5):587-590.
    30. Kalinczuk L, Pregowski J, Mintz GS, Dilcher CE, Kotani J, Kruk M, et al. Incidence and mechanism of late stent malapposition after phosphorus-32 radioactive stent implantation. Am J Cardiol.2003; 92(8):970-972.
    31. Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G, Urbaszek W, et al. Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents:insights from the randomized TAXUS II trial. Circulation.2005; 111(7):900-905.
    32. Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent:should we be cautious? Circulation.2004; 109(6): 701-705.
    33. Miyazawa A, Tsujino I, Ako J, Shimada Y, Courtney BK, Sakurai R, et al. Characterization of late incomplete stent apposition:a comparison among bare-metal stents, intracoronary radiation and sirolimus-eluting stents. J Invasive Cardiol.2007; 19(12):515-518.
    34. Degertekin M, Serruys PW, Tanabe K, Lee CH, Sousa JE, Colombo A, et al. Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions:an intravascular ultrasound analysis. Circulation 2003; 108:2747-2750.
    35. Hong MK, Mintz GS, Lee CW, Park DW, Lee SW, Kim YH, et al. Impact of late drug-eluting stent malapposition on 3-year clinical events. J Am Coll Cardiol. 2007; 50(15):1515-1516.
    36. Feres F, Costa JR Jr, Abizaid A. Very late thrombosis after drug-eluting stents. Catheter Cardiovasc Interv.2006; 68(1):83-88.
    37. Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, et al. Pathology of drug-eluting stents in humans:delayed healing and late thrombotic risk. J Am Coll Cardiol.2006; 48(1):193-202.
    38. Park JS, Kim YJ, Hong GR. Thrombosis and acute myocardial infarction as consequences of very late stent malapposition after implantation of a drug-eluting stent. J Invasive Cardiol.2007; 19(6):E163-E165.
    39. Jo SH, Koo BK, Kim HS. Acute myocardial infarction caused by late stent thrombosis associated with progressive incomplete stent apposition. Can J Cardiol.2007; 23(14):1163.
    40. Zhang F, Qian J, Ge J. Very late stent thrombosis in late stent malapposition after sirolimus-eluting stent implantation. Int Heart J.2007; 48(5):591-596.
    41. Zhang F, Qian J, Ge J. Coexistent in-stent restenosis, late incomplete stent apposition and mural thrombus in a zotarolimus-eluting stent. J Invasive Cardiol. 2008; 20(8):423-425.
    42. Sawada T, Shite J, Shinke T, Tanino Y, Ogasawara D, Kawamori H, et al. Very late thrombosis of sirolimus-eluting stent due to late malapposition:serial observations with optical coherence tomography. J Cardiol.2008; 52(3):290-295.
    43. Min SY, Kim YH, Park SJ. Very late stent thrombosis of sirolimus-eluting stent combined with late stent malapposition and aneurysm formation. J Invasive Cardiol.2009; 21(9):E175-E177.
    44. Balbi M, Fedele M, Bezante GP, Brunelli C, Barsotti A. Acute myocardial infarction related to very late sirolimus-eluting stent thrombosis 6 months after discontinuation of dual antiplatelet therapy. J Cardiovasc Med (Hagerstown). 2010 Mar 4. [Epub ahead of print]
    45. Barison A, de Carlo M, Bellini F, Capozza PF, Lunardini A, Petronio AS. Recurrent episodes of very late stent thrombosis in a patient with aspirin hypersensitivity, stent fracture and malapposition. Acute Card Care.2011; 13(1): 52-54.
    46. Siqueira DA, Abizaid AA, Costa Jde R, Feres F, Mattos LA, Staico R, et al. Late incomplete apposition after drug-eluting stent implantation:incidence and potential for adverse clinical outcomes. Eur Heart J.2007; 28(11):1304-1309.
    47. Cook S, Wenaweser P, Togni M, Billinger M, Morger C, Seiler C, et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation.2007; 115(18):2426-2434.
    48. Lee CW, Kang SJ, Park DW, Lee SH, Kim YH, Kim JJ, et al. Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation. J Am Coll Cardiol.2010; 55(18): 1936-1942.
    49. Ozaki Y, Okumura M, Ismail TF, Naruse H, Hattori K, Kan S, et al. The fate of incomplete stent apposition with drug-eluting stents:an optical coherence tomography-based natural history study. Eur Heart J.2010; 31(12):1470-1476.
    50. Kang SJ, Mintz GS, Park DW, Lee SW, Kim YH, Lee CW, et al. Late and very late drug-eluting stent malapposition:serial 2-year quantitative IVUS analysis. Circ Cardiovasc Interv.2010; 3(4):335-340.
    1. Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346:1773-1780.
    2. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349:1315-1323.
    3. Stone GW, Ellis SG, Cox DA, Hermiller J, O' Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004; 350:221-231.
    4. Serruys PW, Degertekin M, Tanabe K, Abizaid A, Sousa JE, Colombo A, et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (randomized study with the sirolimus-eluting velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions) trial. Circulation 2002; 106:798-803.
    5. Colombo A, Drzewiecki J, Banning A, Grube E, Hauptmann K, Silber S, et al. Randomized study to assess the effectiveness of slow-and moderaterelease polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 2003; 108:788-794.
    6. Stone GW, Ellis SG, Cannon L, Mann JT, Greenberg JD, Spriggs D, et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease:a randomized controlled trial. JAMA2005;294:1215-1223.
    7. Marroquin OC, Selzer F, Mulukutla SR, Williams DO, Vlachos HA, Wilensky RL, et al. A comparison of bare-metal and drug-eluting stents for off-label indications. N Engl J Med.2008; 358(4):342-352.
    8. Zhang F, Ge J, Qian J, Fan B, Wang Q, Ge L, et al. Sirolimus-eluting stents in real-world patients with ST-segment elevation acute myocardial infarction. Int Heart J 2007; 48:303-311.
    9. Camenzind E, Steg PG, Wijns W. Stent thrombosis late after implantation of first-generation drug-eluting stents:a cause for concern. Circulation.2007; 115(11):1440-1455.
    10. Daemen J, Wenaweser P, Tsuchida K, Abrecht L, Vaina S, Morger C, et al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:data from a large two-institutional cohort study. Lancet.2007; 369(9562):667-678.
    11. Kerner A, Gruberg L, Kapeliovich M, Grenadier E. Late stent thrombosis after implantation of a sirolimus-eluting stent. Catheter Cardiovasc Interv.2003; 60: 505-508.
    12. Cheneau E, Pichard AD, Stabile E, Waksman R. Asymptomatic late stent thrombosis after sirolimus stent implantation. Cardiovasc Radiat Med.2004; 5: 57-58.
    13. McFadden EP, Stabile E, Regar E, Cheneau E, Ong AT, Kinnaird T, et al. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet.2004; 364:1519-1521.
    14. Iakovou I, Schmidt T, Bonizzoni E, Ge L, Sangiorgi GM, Stankovic G, et al. Incidence, predictors and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA.2005; 293:2126-2130.
    15. Jensen LO, Maeng M, Kaltoft A, Thayssen P, Hansen HH, Bottcher M, et al. Stent thrombosis, myocardial infarction, and death after drug-eluting and bare-metal stent coronary interventions. J Am Coll Cardiol.2007; 50(5):463-470.
    16. Bavry AA, Kumbhani DJ, Helton TJ, Borek PP, Mood GR, Bhatt DL. Late thrombosis of drug-eluting stents:a meta-analysis of randomized clinical trials. Am J Med.2006; 119(12):1056-1061.
    17. Serruys PW, Ong AT, Piek JJ, Neumann FJ, van der Giessen WJ, Wiemer M, et al. A randomized comparison of a durable polymer Everolimus-eluting stent with a bare metal coronary stent:The SPIRIT first trial. Eurolntervention.2005; 1(1): 58-65.
    18. Ruygrok PN, Desaga M, Van Den Branden F, Rasmussen K, Suryapranata H, Dorange C, et al. One year clinical follow-up of the XIENCE V Everolimus-eluting stent system in the treatment of patients with de novo native coronary artery lesions:the SPIRIT II study. Eurolntervention.2007; 3(3):315-20.
    19. Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, et al. Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease:a randomized trial. JAMA.2008; 299(16): 1903-1913.
    20. Kedhi E, Joesoef KS, McFadden E, Wassing J, van Mieghem C, Goedhart D, et al. Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice (COMPARE):a randomised trial. Lancet.2010; 375(9710):201-209.
    21. Stone GW, Rizvi A, Newman W, Mastali K, Wang JC, Caputo R, et al. Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease. N Engl J Med.2010; 362(18):1663-1674.
    22. Egger M, Ebrahim S, Smith G.D. Where now for meta-analysis? Int J Epidemiol 2002; 31:1-5.
    23. Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, et al. Clinical end points in coronary stent trials:a case for standardized definitions. Circulation.2007; 115(17):2344-2351.
    24. Moher D, Cook DJ, Eastwood S, Olkin I, Rennie D, Stroup DF. Improving the quality of reports of meta-analyses of randomised controlled trials:the QUOROM statement. Quality of Reporting of Meta-analyses. Lancet 1999; 354: 1896-1900.
    25. Altman DG, Schulz KF. Statistics notes:concealing treatment allocation in randomised trials. BMJ 2001; 323:446-447.
    26. Juni P, Altman DG, Egger M. Systematic reviews in health care:assessing the quality of controlled clinical trials. BMJ 2001; 323:42-46.
    27. Greenland S. Invited commentary:a critical look at some popular meta-analytic methods. Am J Epidemiol 1994; 140:290-296.
    28. Juni P, Witschi A, Bloch R, Egger M. The hazards of scoring the quality of clinical trials for meta-analysis. JAMA 1999; 282:1054-1060.
    29. Mantel N, Haenszel W. Statistical aspects of the analysis of data from retrospective studies of disease. J Natl Cancer Inst 1959; 22:719-748.
    30. DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials 1986; 7:177-188.
    31. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ 2003; 327:557-560.
    32. Begg CB, Mazumdar M. Operating characteristics of a rank correlation test for publication bias. Biometrics 1994; 50:1088-1101.
    33. Doostzadeh J, Clark LN, Bezenek S, Pierson W, Sood PR, Sudhir K. Recent progress in percutaneous coronary intervention:evolution of the drug-eluting stents, focus on the XIENCE V drug-eluting stent. Coron Artery Dis 2010; 21: 46-56.
    34. Joner M, Quee SC, Coleman L, Skorija K, Wilson P, Kolodgie FD, et al. Competitive comparison of reendothelialization in drug eluting stents. Circulation. 2006; 114:11-506.
    35. Joner M, Nakazawa G, Finn AV, Quee SC, Coleman L, Acampado E, et al. Endothelial cell recovery between comparator polymer-based drug-eluting stents. J Am Coll Cardiol.2008; 52:333-342.
    36. Stone GW, Moses JW, Ellis SG, Schofer J, Dawkins KD, Morice MC, et al. Safety and efficacy of sirolimus-and paclitaxel-eluting coronary stents. N Engl J Med.2007; 356:998-1008.
    37. Wiemer M, Serruys PW, Miquel-Hebert K, Neumann FJ, Piek JJ, Grube E, et al. Five-year long-term clinical follow-up of the XIENCE V everolimus eluting coronary stent system in the treatment of patients with de novo coronary artery lesions:the SPIRIT FIRST trial. Catheter Cardiovasc Interv.2010; 75(7): 997-1003.
    38. Onuma Y, Serruys PW, Kukreja N, Veldhof S, Doostzadeh J, Cao S, et al. Randomized comparison of everolimus-and paclitaxel-eluting stents:pooled analysis of the 2-year clinical follow-up from the SPIRIT Ⅱ and Ⅲ trials. Eur Heart J.2010; 31(9):1071-1078.
    39. Jensen LO, Thayssen P, Tilsted HH, Ravkilde J, Junker A, Hansen HS, et al. Rationale and Design of a Randomized Clinical Comparison of Everolimus-Eluting (Xience V/Promus) and Sirolimus-Eluting (Cypher Select+) Coronary Stents in Unselected Patients with Coronary Heart Disease. Cardiology. 2010; 116(2):73-78.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700