风冷多联机在西安地区的除霜应用研究
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Study on Defrosting Application of Air-cooled Multi-connection in Xi'an Area
  • 作者:王继前 ; 狄育慧 ; 冯璐 ; 徐青松
  • 英文作者:Wang Jiqian;Di Yuhui;Feng Lu;Xu Qingsong;Xi'an Polytechnic University;Shaanxi Construction & Installation Group limited comp;
  • 关键词:多联机 ; 结霜 ; 除霜 ; 控制理论 ; 参考
  • 英文关键词:Multi-line;;Frosting;;Defrost;;Control theory;;Reference
  • 中文刊名:制冷与空调(四川)
  • 英文刊名:Refrigeration & Air Conditioning
  • 机构:西安工程大学;陕西建工安装集团有限公司;
  • 出版日期:2019-04-28
  • 出版单位:制冷与空调(四川)
  • 年:2019
  • 期:02
  • 语种:中文;
  • 页:105-109
  • 页数:5
  • CN:51-1622/TB
  • ISSN:1671-6612
  • 分类号:TU83
摘要
通过现场抽样调查西安地区多联机冬季除霜现状,得出西安地区现有多联机系统冬季运行结霜特点,并提出两种判断结霜除霜控制的理论,为合理使用多联机提供参考
        Through on-the-spot investigation of the current status of multi-line winter defrosting in Xi'an area, the characteristics of the existing multi-line system winter frost operation in Xi'an area have been derived, and two theories for judging the frosting and defrosting control have been proposed, providing reference for rational use of multiple connections.
引文
[1]Lin Daoguang,Li Xiaohua,Tang Jingli.Defrosting for air source heat pump[J].Buliding Energy Saving,2013,41(4):30-33.
    [2]董建锴,姜益强,姚杨,等.空气源热泵相变蓄能除霜特性实验研究[J].湖南大学学报(自然科学版),2011,38(1):18-22.
    [3]王新利,熊美兵,冯明坤,等.多联机空调器智能除霜控制研究[J].制冷,2014(2):29-31.
    [4]董建锴,张龙,姜益强,等.不同相变蓄能器对多联机空气源热泵蓄能除霜性能影响[J].太阳能学报,2016,37(9):2856-2861.
    [5]张杰,兰菁,杜瑞环,等.几种空气源热泵除霜方式的性能比较[J].制冷学报,2012,33(2):47-49.
    [6]曲明璐,邓仕明,董建锴,等.空气源热泵蓄能换向除霜对室内热舒适的影响[J].暖通空调,2013,43(4):76-79.
    [7]黄东,袁秀玲.风冷热泵冷热水机组热气旁通除霜与逆循环除霜性能对比[J].西安交通大学学报,2006,40(5):539-543.
    [8]韩志涛,姚杨,马最良,等.空气源热泵误除霜特性的实验研究[J].暖通空调,2006,36(2):15-19.
    [9]王伟,李林涛,盖轶静,等.空气源热泵误除霜事故简析[J].制冷与空调,2015,15(3):64-71.
    [10]JK Dong,SMDeng,YQJiang,et a1.An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump[J].Applied Thermal Engineering,2012,37:380-387.
    [11]W Wang,Q C Guo,W P Lu,et a1.A generalized simple model for predicting frost growth on cold Flat plate[J].International Journal of Refrigeration,2012,35(2):475-486.
    [12]W Wang,Y C Feng,J H Zhu,et a1.Perform-ances of air source heatpump system for a kind of mal-defrost phenomenon appearing in moderate cli-mate conditions[J].Applied Energy,2013,112(4):1138-1145.