汶川地震实测波作用下高耸进水塔结构损伤开裂分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
以某高耸进水塔为例,采用ADINA结构分析软件建立了结构-水体动力耦合的三维非线性有限元模型,利用汶川地震中某坝顶处所测得的地震波进行相应的修正处理,作为模型结构的地震动输入,研究了进水塔在正常蓄水位组合地震荷载工况下的地震反应,并分析了其抗震安全性。结果表明,高耸进水塔在实测地震波作用下局部出现损伤开裂,但整体结构仍能确保抗震安全性。
Taking a high-rise intake tower for an example,3D nonlinear finite element model of structure-water body coupling interaction is established by using software ADINA.The monitored seismic wave of dam crest in Wenchuan earthquake is modified and taken as input of the model.And then the seismic response of intake tower and its aseismic safety are analyzed under the conditions of seismic load in normal water level.The results show that the high-rise intake tower appears local damage-cracking under the action of monitored seismic wave,but the whole structure can ensure aseismic safety.
引文
[1]赵晓红,张燎军,龚存燕.紫坪铺水电站#2泄洪排砂进水塔震后抗震复核分析[J].水电能源科学,2010,28(8):91-93.
    [2]Jeeho Lee,Gregory L Fenves.A Plastic-damage ConcreteModal for Earthquake Analysis of Dams[J].Earth-quake Engineering&Structural Dynamics,1998,27(9):937-956.
    [3]ADINA R&D,Inc..ADINA Theory and ModelingGuide Volume I:ADINA Solid&Structures[Z].USA,Watertown:ADINA R&D,Inc.,2005.
    [4]江见鲸,陆新征,叶列平.混凝土结构有限元分析[M].北京:清华大学出版社,2005.
    [5]陈厚群,徐泽平,李敏.汶川大地震和大坝抗震安全[J].水利学报,2008,39(10):1 158-1 167.
    [6]中国水利水电科学研究院.水工建筑物抗震设计规范(DL5073-2000)[S].北京:中国电力出版社,2001.