摘要
该文介绍石圪台煤矿31206上覆采空区防灭火工程供水系统改造的方案,包括改造背景、方案制定、以及改造施工情况,分析该套改造系统的改造原则,在既保证原有供排水系统可靠性,又必须综合考虑防灭火工程用水量、供水压力、管路损耗等各方面因素,在确保供应矿区用水,又不会造成资源浪费,以工程量最小,改造费用最少,方案最优,确保系统尽早尽快投入,为整体灭火工程的实施提高了可靠保证,也为供排水系统的临时必要改造时,系统的设计施工、方案的实施提供了参考,略有考虑不周之处,望多提宝贵意见,相互交流。
By considering the factors such as water consumption,water supply pressure and pipeline loss of fire prevention and extinguishing project,and ensuring the reliability of the original water supply and drainage system and the water use in the mining area,the transformation scheme of water supply system of the fire prevention and extinguishing project for No.31206 working face's overlying goaf in Shigetai coal mine was proposed.