摘要
以典型固体-气体复合绝缘缺陷为参考,设计自由金属颗粒、悬浮金属块、尖端、沿面污染4种典型绝缘缺陷模型。采用2种不同电压下雷电冲击电压、振荡雷电冲击电压、操作冲击电压、振荡操作冲击电压对设计模型进行试验和分析,采集试验数据,分析放电特征,为相关检测评价提供依据。
Based on typical solid-gas composite insulation defects, four typical insulation defect models are designed which are free metal particles, suspended metal blocks, tip and surface contamination.Lightning impulse voltage, oscillating lightning impulse voltage, switching impulse voltage and oscillating switching impulse voltage under two different voltages are used to test and analyze the design model.The test data are collected to analyze the discharge characteristics which provides a basis for relevant detection and evaluation.
引文
[1] N.Hayakawa,Y.Yoshitake,N.Koshino,et al.Impulse Partial Discharge Characteristics and Their Mechanisms under Non-uniform Electric Field in N2/SF6 Gas Mixtures[J].IEEE Transactions on Dielectrics and Electrical Insulation,2005,12(5):1035-1042.
[2] Y.Hoshina,M.Sato,M.Shiiki,et al.Lightning impulse breakdown characteristics of SF6 alternative gases for gas-insulated switchgear[J].IEE Proc.-Sci.Meas.Technol,2006,153(1):1-6.
[3] Zhao Xuefeng,Yao Xiu,Guo Zhifeng,et al.Characteristics and Development Mechanisms of Partial Discharge in SF6 Gas Under Impulse Voltages[J].IEEE Transactions on Plasma Science,2011,39(2):668-674.
[4] 周桂平,唐佳能,金鑫.分布式局部放电检测技术在高压电缆交接试验中的应用[J].东北电力技术,2016,37(7):14-16.
[5] 周远翔,沙彦超,聂德鑫.交直流复合电压下油中局部放电的起始过程[J].高电压技术,2012,38(5):1163-1171.
[6] 伍志荣,聂德鑫,陈江波.特高压变压器局部放电试验分析[J].高电压技术,2010,36(1):54-61.
[7] 聂德鑫,伍志荣,罗先中.特高压变压器套管局部放电试验技术分析[J].高电压技术,2010,36(6):1448-1454.
[8] 牛李,应勇,赵义松.某220 kV变压器长时感应电压带局部放电测量试验局放量超标分析[J].东北电力技术,2013,34(8):34-35.
[9] 沙彦超,周远翔,聂德鑫.直流电压下变压器油纸绝缘局部放电的发展过程[J].高电压技术,2014,40(2):526-532.
[10] 李斌,曾辉明,赵义松,等.GIS局部放电特高频检测系统标定方法应用研究[J].东北电力技术,2017,38(6):4-8.