特定振动频率对离心机转速和血型血清学检查结果影响评价
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Evaluation of the effect of specific vibration frequency on the rotational speed of centrifuge and blood group serological typing results
  • 作者:范秀 ; 白晓莹 ; 肖军 ; 雷慧芬 ; 刘娟 ; 李景琦 ; 李小薇 ; 樊凤艳
  • 英文作者:FAN Xiu;BAI Xiaoying;XIAO Jun;LEI Huifen;LIU Juan;LI Jingqi;LI Xiaowei;FAN Fengyan;Department of Blood Transfusion, Air Force General Hospital,PLA;
  • 关键词:振动 ; 血型血清学检查 ; 影响评价 ; 离心机
  • 英文关键词:vibration;;blood group;;serological typing of blood group;;impact assessment;;centrifuge
  • 中文刊名:BLOO
  • 英文刊名:Chinese Journal of Blood Transfusion
  • 机构:空军总医院输血科;
  • 出版日期:2019-04-25
  • 出版单位:中国输血杂志
  • 年:2019
  • 期:v.32
  • 基金:“十二五”军队课题面上项目(CKJ13J013)
  • 语种:中文;
  • 页:BLOO201904004
  • 页数:4
  • CN:04
  • ISSN:51-1394/R
  • 分类号:16-19
摘要
目的评价模拟飞行特定振动频率对Labnet 6c离心机转速和血型血清学检查结果的影响。方法测量平地振动条件和平地非振动条件下Labnet 6c离心机在1 500 r/min档及3 000 r/min档时的实际转速。血型血清学专用离心机平地条件检测标准B型RhD阳性(B~+)红细胞与倍比稀释抗-RhD IgG和抗-B IgM血清样本反应强度,分别筛选一个凝集强度为4+、3+、2+、1+、阴性时稀释倍数。评价平地和振动条件对于Labnet 6c离心机4+、3+、2+、1+、阴性抗-RhD IgG和抗-B IgM样本的检测结果。结果平地振动条件下,在1 500 r/min档及3 000 r/min档Labnet 6c离心机转速与平地条件转速均无统计学差异(P>0.05);Labnet 6c离心机1 500 r/min离心1 min进行检测时红细胞不能形成细胞扣,不适合进行血型血清学检查;3 000 r/min 15s离心可以使检测红细胞形成细胞扣,适合进行血型血清学检查;标定好的4+、3+、2+、1+、阴性抗-B IgM抗体、抗-D IgG抗体分别与标准B~+红细胞进行反应,平地非振动条件Labnet 6c离心机检测结果、平地振动条件Labnet 6c离心机检测结果、平地非振动条件血型血清学专用离心机检测结果完全一致,三者两两比较均Kappa值=100%。结论模拟大型客机飞行特定振动频率对Labnet 6c离心机转速和血型血清学检查结果无明显影响。
        Objective To evaluate the effects of specific vibration frequency of simulated flight on the rotational speed of Labnet 6 c centrifuge and the blood group serological typing results. Methods The actual rotational speed of Labnet 6 c centrifuge at 1 500 r/min or 3 000 r/min gear was measured under the non-vibrating and vibratory condition with level laying. The agglutination strength between standard B(+) RBCs and anti-RhD IgG or anti-B IgM serum samples with tiraes ratio dilution, i.e. agglutination strength with 4+, 3+, 2+, 1+ or negative, respectively, was detected by standard blood group serological centrifuge under level condition.The effect of level laying and vibratory condition of Labnet 6 c centrifuge on the results of anti-RhD IgG and anti-B IgM samples was investigated. Results When the rotational speed under simulated vibration(at 1 500 r/min or 3 000 r/min gear) with level laying was compared with that of non-vibrating condition, no significant difference was observed(P>0.05). The RBCs couldn′t form cell clasp after the centrifugation at 1 500 r/min for 1 min, which was, hence, not suitable for blood group serological typing; while cell clasp can be formed after the centrifugation at 3 000 r/min for 15 s, which was adapted for blood group serological typing. The calibrated 4+, 3+, 2+, 1+, negative anti-B IgM antibody, and anti-D IgG antibody were reacted with standard B(+) RBCs. The blood group serology typing results among three conditions(Labnet 6 c centrifuge under non-vibrating or vibratory condition with level laying, and standard blood group serological centrifuge under level condition) were all in accordance, with the Kappa value of 100% by multiple comparison with each other. Conclusion The specific vibration frequency of simulated large airliner has no significant effect on the speed of Labnet 6 c centrifuge and blood group serological typing results.
引文
[1] 安瑞卿,陈良恩,张晓丽.关于发展我军空中医院的总体构想.空军医学杂志,2011,27(4):185-189.
    [2] 魏少平,李柱,雷慧芬,等.客机运输对不同保存期悬浮红细胞质量影响的研究.中国输血杂志,2017,30(9):1000-1003.
    [3] 临床输血技术规范.卫医发[2000]184号.
    [4] 军用装备实验室环境试验方法,GJB150.16A-2009.
    [5] 汪德清.输血技术操作规程.北京:人民卫生出版社.2016:15-19,39-41.
    [6] 刘潘,夏琳.凝聚胺法与微柱凝胶法交叉配血阳性结果分析.临床血液学杂志(输血与检验),2017,30(4):631-633.
    [7] 黄亚男.凝聚胺技术的优越性以及在临床输血检验中的应用效果观察.中国医药指南,2016,14(34):88-89.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700