常规三维容积内插屏气检查序列与自由呼吸StarVIBE序列T1WI肝脏图像质量对比
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Comparative on image quality of liver between conventional 3D volumetric interpolated breath-hold examination sequence and free-breathing StarVIBE sequence T1WI
  • 作者:李武超 ; 王頔 ; 郑念华 ; 刘远成 ; 田冲 ; 翟茂雄 ; 王少彧 ; 王荣品
  • 英文作者:LI Wuchao;WANG Di;ZHENG Nianhua;LIU Yuancheng;TIAN Chong;ZHAI Maoxiong;WANG Shaoyu;WANG Rongpin;Department of Radiology,Guizhou Provincial People's Hospital;Division of MR,Siemens Healthcare Sector,Siemens Ltd.;
  • 关键词:肝脏 ; 磁共振成像 ; 屏气
  • 英文关键词:Liver;;Magnetic resonance imaging;;Breath holding
  • 中文刊名:ZYXX
  • 英文刊名:Chinese Journal of Medical Imaging Technology
  • 机构:贵州省人民医院放射科;西门子医疗系统有限公司磁共振事业部;
  • 出版日期:2018-07-20
  • 出版单位:中国医学影像技术
  • 年:2018
  • 期:v.34;No.302
  • 基金:贵州省科技厅联合基金(黔科合LH字[2015]7115);; 贵州省科技计划项目(黔科合基础[2016]1096);; 贵州省人民医院博士基金(GZSYBS[2015]02号);; 贵州省科学技术基金(黔科合基础[2017]1109);; 贵州省高层次创新型人才培养计划(QZSYQCC[2015]001)
  • 语种:中文;
  • 页:ZYXX201807046
  • 页数:5
  • CN:07
  • ISSN:11-1881/R
  • 分类号:139-143
摘要
目的对比分析常规三维容积内插屏气检查(VIBE)与StarVIBE序列的图像质量,探讨StarVIBE序列自由呼吸扫描在肝脏T1WI中的应用价值。方法对48例超声提示肝脏病变患者行StarVIBE序列自由呼吸扫描及常规VIBE序列屏气扫描,根据患者能否配合屏气16s分为无法屏气组(n=24)及配合屏气组(n=24);采用"5分法"对肝脏边缘锐利度、肝脏血管清晰度、病变清晰度、伪影、脂肪抑制效果及图像总体质量进行主观评分,并计算平扫信号强度变异系数(CV)及增强后病灶肝脏信号比(LLR);比较组内2序列间及2组间StarVIBE序列的图像质量差异。结果无法屏气组StarVIBE序列图像的主观评分及定量评估参数值均高于常规VIBE序列(P均<0.05);配合屏气组StarVIBE序列图像病灶清晰度(平扫)、伪影及脂肪抑制效果评分低于常规VIBE序列(P均<0.05),而2序列间其余主观评分及定量评估差异均无统计学意义(P均>0.05)。2组间StarVIBE序列LLR差异有统计学意义(P<0.05),各项主观评分及CV差异均无统计学意义(P均>0.05)。结论在肝脏T1WI中,对于能配合屏气患者,StarVIBE序列图像质量略差于常规VIBE序列;而对于无法屏气患者,StarVIBE序列可获得更佳图像质量。
        Objective To compare image quality of liver on conventional three dimensional-volumetric interpolated breathhold examination(VIBE)and StarVIBE sequence TIWI,and to investigate the application value of StarVIBE sequence.Methods Totally 48 patients with ultrasound suggested liver lesions underwent StarVIBE sequence free-breathing and conventional VIBE sequence breath-hold scanning.According to whether the patient cooperated with breath-holding 16s,the patients were divided into unable to hold breath group(n=24)and able to hold breath group(n=24).The liver edge sharpness,hepatic vessel clarity,lesion conspicuity,artifacts,fat saturation,and overall image quality were subjectively scored using "five-point method".The precontrast signal coefficient of variation(CV)and the postcontrast lesion-to-liver signal intensity ratios(LLR)were measured and calculated.The image quality of two sequences within the group and the image quality of StarVIBE sequence between two groups were compared.Results For non-breath-hold group,the subjective scoring and quantitative evaluation value of images quality of StarVIBE sequence were higher than those of conventional VIBE sequence(all P<0.05).For breath-hold group,scores of lesion conspicuity(pre-contrast),artifacts and fat saturation of StarVIBE sequence were lower than those of conventional VIBE sequence(all P<0.05),while the remaining subjective scoring and quantitative evaluation had no significant statistical differences between the two sequences(all P>0.05).LLR of StarVIBE sequence between two groups had significant statistical difference(P<0.05),while no significant statistical difference was found in CV and all subjective scoring(all P>0.05).Conclusion For liver T1WI,in breath-hold patients,image quality of StarVIBE sequence is slightly poorer than that of conventional VIBE sequence,while in non-breath-hold patients,StarVIBE sequence can obtain better image quality.
引文
[1]Chandarana H,Block KT,Winfeld MJ,et al.Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI.Eur Radiol,2014,24(2):320-326.
    [2]Shimizu S,Shirato H,Xo B,et al.Three-dimensional movement of a liver tumor detected by high-speed magnetic resonance imaging.Radiother Oncol,1999,50(3):367-370.
    [3]Morani AC,Vicens RA,Wei W,et al.CAIPIRINHA-VIBE and GRAPPA-VIBE for liver MR imaging at 1.5T:A comparative in vivo patient study.J Comput Assist Tomogr,2015,39(2):263-269.
    [4]Azevedo RM,de Campos RO,Ramalho M,et al.Free-breathing3DT1-weighted gradient-echo sequence with radial data sampling in abdominal MRI:Preliminary observations.AJR Am J Roentgenol,2011,197(3):650-657.
    [5]Sireesha,Yedururi,HyunSeon,et al.Free-breathing radial volumetric interpolated breathhold examination vs breath-hold cartesian volumetric interpolated breath-hold examination magnetic resonance imaging of the liver at 1.5T.World J Radiol,2016,8(7):707-715.
    [6]Weiss J,Taron J,Othman AE,et al.Feasibility of self-gated isotropic radial late-phase MR imaging of the liver.Eur Radiol,2017,27(3):985-994.
    [7]庄霞梅,金科,王海,等.MRI优化的三维容积内插快速扰相梯度回波序列在胎儿神经系统检查中的应用.中国医学影像技术,2016,32(7):1119-1123.
    [8]Chandarana H,Feng L,Block TK,et al.Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing,parallel imaging,and goldenangle radial sampling.Invest Radiol,2013,48(1):10-16.
    [9]Kim SG,Freed M,Leite APK,et al.Separation of benign and malignant breast lesions using dynamic contrast enhanced MRI in a biopsy cohort.J Magn Reson Imaging,2017,45(5):1385-1393.
    [10]Sohns JM,Menke J,Schwarz A,et al.Incidental findings in cardiac magnetic resonance imaging:Superiority of bSSFP over T1w-HASTE for extra-cardiac findings assessment.Int J Cardiovasc Imaging,2017,33(10):1581-1587.
    [11]马文婷,黎金葵,翟亚楠,等.CAIPIRINHA-Dixon-TWIST-VIBE技术诊断小肝癌的研究进展.中国医学影像技术,2017,33(8):1277-1280.
    [12]Runge VM,Richter JK,Heverhagen JT.Speed in clinical magnetic resonance.Invest Radiol,2017,52(1):1-17.

© 2004-2018 中国地质图书馆版权所有 京ICP备05064691号 京公网安备11010802017129号

地址:北京市海淀区学院路29号 邮编:100083

电话:办公室:(+86 10)66554848;文献借阅、咨询服务、科技查新:66554700