Introduction

Colonoscopic simulators offer the opportunity for skill acquisition in the pre-clinical setting. Available simulators vary widely with respect to fidelity and technological sophistication. We hypothesize that novice learners can acquire basic colonoscopic skills using simulators however fidelity of the simulator does not make a difference.

Methods

Novice third year medical students were randomly assigned to practice on a low- fidelity (lo-fid group) or high-fidelity (hi-fid group) colonoscopy model. The low-fidelity model is described in module 16 of the ACS/APDS Surgical Skills Curriculum for Residents, Phase 1: Basic/Core Skills and Tasks. The high-fidelity model was the AccuTouch colonoscopy simulator, Immerson Medical (AccuTouch-CS). Both groups had 16 students and were given standard instruction by an expert. Both groups were pre and post tested on level 1 of the AccuTouch-CS. The hi-fid group practiced on level 2 and 4 of the AccuTouch-CS while the low-fid group practiced on the low-fidelity model for 2 sessions of 1 hour each. The computer based evaluation parameters available on the AccuTouch-CS were used to compare performances.

Results

Hi-fid group Mean ScoreLo-fid group Mean Score
ParameterPrePostPrePost
Total Time105110371112?/sup>835
Insertion Time426?/sup>331481?/sup>255
Withdrawal Time609716633574
Maximum Scope Depth119120119121
Percentage Visualized86?/sup>9688?/sup>97
Total Path Length418482540522
Percentage Redout8.29.611.79.2
Total Air Insufflated2246166926782114
Percentage Air Left95919795