Cutaneous microvascular reactivity and aortic elasticity in coronary artery disease: Comparison of the laser Doppler flowmetry and echocardiography
详细信息    查看全文
文摘
The recorded microvascular measurements by laser doppler were decreased in patients with coronary artery disease(CAD) Aortic strain and aortic distensibility were decreased in patients with CAD history recorded with echocardiography There were no correlations between microvascular measurements and aortic measurements (aortic strain and distensibility) Both aorta and cutaneus microcirculations might be independtly disturbed in patients with CAD
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083