Volar locking plate (VLP) versus non-locking plate (NLP) in the treatment of die-punch fractures of the distal radius, an observational study
详细信息    查看全文
文摘
class="listitem" id="list_ulist0010">
class="label">•

Preoperative CT and reconstruction is essential to diagnose Die-punch fractures of distal radius.

class="label">•

VLP could better maintain the reduction after operation than NLP.

class="label">•

Patients treated by VLP or NLP could obtain similar functional outcomes at the follow-up>1 year.