Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings
We reviewed 27 patients who underwent revision for an adverse local tissue reaction (ALTR) secondary to corrosion at the head-neck junction with MoP bearings. Serum cobalt and chromium levels were elevated in all cases, with a mean cobalt of 11.2 ppb and chromium of 2.2 ppb. Patients underwent modular bearing exchange, including a ceramic head with a titanium sleeve in 23 of 27 cases with only one recurrence of ALTR in one of the four patients not treated with a ceramic head. The diagnosis of ALTR secondary to corrosion is associated with cobalt levels of >1 ppb with cobalt levels elevated above chromium. Retention of a well-fixed stem and modular exchange to a ceramic head leads to resolution of symptoms and decreases in metal levels.