Unified correlation for heat transfer during boiling in plain mini/micro and conventional channels
详细信息    查看全文
文摘
Presents a new correlation applicable to both macro and mini/micro channels Correlation verified with 4852 data points from 137 data sets from 81sources Data include 30 fluids, diameter 0.38 to 27.1 mm, and reduced pressure 0.0046 to 0.787. Mean absolute deviation 18.6 %, much lower than other correlations
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083