X-ray Structure Analysis of Free-Standing Lipid Membranes Facilitated by Micromachined Apertures
详细信息    查看全文
文摘
Silicon and Teflon substrates have been structured by wet etching and a focused ion beam (FIB) to obtain verydefined, clean apertures. Planar, free-standing lipid membranes (black lipid membranes (BLM)) with enhanced long-term stability have been prepared on these apertures by the methods of Montal and Müller1,2 as well as Müller andRudin.3 The stability and geometric control enables the use of X-ray analysis of free-standing single bilayers. Withthe presented setup, simultaneous structural and electrophysiological measurements will become feasible.