222Rn distribution coefficient in various organic scintillation cocktails
详细信息    查看全文
  • 作者:Magdalena Długosz-Lisiecka…
  • 关键词:PicoRad detector ; Liquid scintillation counting LSC ; 222Rn in the air
  • 刊名:Journal of Radioanalytical and Nuclear Chemistry
  • 出版年:2016
  • 出版时间:February 2016
  • 年:2016
  • 卷:307
  • 期:2
  • 页码:869-874
  • 全文大小:536 KB
  • 参考文献:1.PAA Annual Report, Activities of the President of National Atomic Energy Agency (PAA) and assessment of nuclear safety and radiological protection in Poland in 2013, Warszaw 2014
    2.Przylibski TA (1996) Zmienność koncentracji radonu w powietrzu Jaskini Niedźwiedziej w Kletnie (Sudety). Prz Geol 44(9):942–944
    3.ICRP (2013) Directive 2013/59/Euratom of 5 December 2013, Basic safety standards for protection against the dangers arising from exposure to ionising radiation. Off J Eur Union L13:1–73
    4.Olszewski J (2010) Assessment of radiation exposure of miners to radon and its daughter products in selected non-ferrous metal mines. Med Pr 61(6):635–639
    5.Washington JW (1996) Gas partitioning of dissolved volatile organic compounds in the vadose zone: principles, temperature effects and literature review. Groundwater 34(4):709–718CrossRef
    6.Bem H, Olszewski M, Kaczmarek A (2004) Concentration of selected natural radionuclides in the thermal groundwater of Uniejów Poland. Nukleonika 49(1):1–5
    7.Grabowski P, Długosz M, Szajerski P, Bem H (2010) A comparison of selected natural radionuclide concentrations in the thermal groundwater of Mszczonów and Cieplice with deep wellwater from Łodz city Poland. Nukleonika 55(2):181–186
    8.Prichard MH, Marien K (1983) Desorption of radon from activated carbon into a liquid scintillator. Anal Chem 55(1):155–157CrossRef
    9.Schroeder M, Vanags C, Hess U (1989) An activated charcoal-based liquid scintillation-analyzed airborne Rn detector. Health Phys 57(1):9–148CrossRef
    10.Gudjónsson GI, Theodórsson P, Sigurdsson K, Kozak K, Grzadziel D (2008) a study of the simple open-vial liquid scintillation method for measurement of radon in air. Work presented on The international conference on advances in liquid scintillation spectrometry davos, Switzerland, 25–30 May 2008
    11.Bem H, Bem EM, Chruścielewski W, Skalski H (2000) Temperature calibration of Pico-Rad detectors for radon measurement. Int J Occup Med Environ Health 13(2):147–154
    12.Stawarz O, Karpińska M, Mamont-Cieśla K (2006) Investigation of the influence of high humidity and exposure duration on the measurement results of radon concentration by means of PicoRad system in the CLOR calibration chamber, Proceedings of the IV All-polish conference on radiochemistry and nuclear chemistry 9–11 May 2005, Kraków-Przegorzały, Poland, Nukleonika, 51(2):53–57
    13.Chau ND (2008) Measurement of radon concentration in the air by PicoRad detectors. Nukleonika 53(Suppl 2):S21–S24
    14.Bem H, Plota U, Staniszewska M, Bem EM, Mazurek D (2013) Radon concentrations in kindergartens and schools. J Radioanal Nucl Chem 295:2229–2232CrossRef
    15.Barbosa EQ, Galhardi JA, Bonotto DM (2014) The use of radon (Rn-222) and volatile organic compounds in monitoring soil gas to localize NAPL contamination at a gas station in Rio Claro, São Paulo State, Brazil. Radiat Meas 66:1–4CrossRef
    16.Cantaloub M, Higginbotham J, Semprini L (1997) The determination of Rn partition coefficients for several liquid scintillation cocktails. Proceedings, 43rd annual conference on bioassay, analytical and environmental radioactivity, Chareleston S.C., Nov 9–13 (1997)
  • 作者单位:Magdalena Długosz-Lisiecka (1)
    Agnieszka Borkowska (1)
    Jerzy Olszewski (2)

    1. Technical University of Lodz, Wróblewskiego 15, 90-924, Lodz, Poland
    2. Department of Radiation Protection, Nofer Institute of Occupational Medicine, Teresy 8, 91-348, Lodz, Poland
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Nuclear Chemistry
    Physical Chemistry
    Nuclear Physics, Heavy Ions and Hadrons
    Diagnostic Radiology
    Inorganic Chemistry
  • 出版者:Akad茅miai Kiad贸, co-published with Springer Science+Business Media B.V., Formerly Kluwer Academic
  • ISSN:1588-2780
文摘
A set of solvents and commercially available scintillation cocktails were tested to provide inexpensive solvents, which can be applied directly for 222Rn elution from the charcoal vials used for indoor radon determination by means of Pico-Rad detectors. The addition of ethanol provides faster and more accurate transfer of the Rn from the charcoal. This study investigates the ability of solvents added directly to charcoal to efficiently displace radon from the charcoal into the gas and/or solvent phases which may be in close proximity to the charcoal. Keywords PicoRad detector Liquid scintillation counting LSC 222Rn in the air