Adaptive Harmonic Detection Control of Grid Interfaced Solar Photovoltaic Energy System with Power Quality Improvement
详细信息    查看全文
  • 作者:B. Singh (1)
    S. Goel (2)

    1. Department of Electrical Engineering
    ; IIT ; Delhi ; India
    2. Northern Regional Load Despatch Centre
    ; Katwaria Sarai ; New Delhi ; India
  • 关键词:Solar photovoltaic ; Harmonics elimination ; MPPT ; Neutral current compensation
  • 刊名:Journal of The Institution of Engineers (India): Series B
  • 出版年:2015
  • 出版时间:March 2015
  • 年:2015
  • 卷:96
  • 期:1
  • 页码:37-45
  • 全文大小:862 KB
  • 参考文献:1. R. Teodorescu, M. Liserre, P. Rodriquez, / Grid converters for photovoltaic and wind power systems (Wiley, United Kingdom, 2011) CrossRef
    2. K.R. Padiyar, / FACTS controllers in power transmission and distribution (New Age International (P) Limited Publishers, New Delhi, 2007)
    3. IEEE Recommended Practices and Requirement for Harmonic Control on Electric Power System, IEEE Std. 519, 1992
    4. B. Yu, M. Matsui, G. Yu, A review of current anti-islanding methods for photovoltaic power system. Sol. Energy 84, 745鈥?54 (2010) CrossRef
    5. Limits for Harmonic Current Emissions, International Electrotechnical Commission IEC-61000-3-2, 2000
    6. R. Mechouma, B. Azoui, M. Chaabane, Three-phase grid connected inverter for photovoltaic systems, a review, in / International Conference on Renewable Energies and Vehicular Technology, 2012
    7. B. Singh, J. Solanki, A comparison of control algorithms for DSTATCOM. IEEE Trans. Industr. Electron. 56(7), 2738鈥?745 (2009) CrossRef
    8. G. Bhuvaneswari, M.G. Nair, Design, simulation and analog circuit implementation of a three phase shunt active filter using the ICos鈭?algorithm, in / Conference IEEE PEDS鈥?5, 1, January 2006
    9. B. Singh, P. Jayaprakash,T.R. Somayajulu, D.P. Kothari, A. Chandra, K. Al-Haddad, Integrated three-leg VSC with a zig-zag transformer based three-phase four-wire DSTATCOM for power quality improvement, in / Industrial Electronics, IECON 2008. 34th Annual Conference of IEEE, pp. 796鈥?01, 10鈥?3 November 2008
    10. A.K. Verma, B. Singh, D.T. Sahani, Grid interfaced solar photovoltaic power generating system with power quality improvement at ac mains, in / Proceedings of IEEE ICSET 2012, Kathmandu, Nepal, October 2012
    11. Y. Mahmoud, W. Xiao, H.H. Zeineidm, A simple approach to modeling and simulation of photovoltaic modules. IEEE Trans. Sustain. Energy 3(1), 185鈥?86 (2012) CrossRef
    12. M. Ganta, N.P. Reddy, T. Akshitha, R. Seyezhai, Simple and efficient implementation of two-phase interleaved boost converter for renewable energy source. Int. J. Emerg. Technol. Adv. Eng. 2(4), 676鈥?81 (2012)
    13. T. Esram, P.L. Chapman, Comparison of photovoltaic array maximum power point tracking techniques. IEEE Trans. Energy Convers. 22(2), 439鈥?49 (2007) CrossRef
    14. A. Safari, S. Mekhilef, Simulation and hardware implementation of incremental conductance MPPT with direct control method using cuk converter. IEEE Trans. Industr. Electron. 58(8), 1154鈥?161 (2011) CrossRef
    15. M.K. Mishra, A. Ghosh, A. Joshi, H.M. Suryawanshi, A novel method of load compensation under unbalanced and distorted voltages. IEEE Trans. Power Delivery 22(1), 288鈥?95 (2007) CrossRef
    16. G.M. Lee, D.-C. Lee, J.-K. Seok, Control of series active power filters compensating for supply voltage unbalance and current harmonics. IEEE Trans. Industr. Electron. 51(1), 132鈥?39 (2004) CrossRef
    17. Y. Zhang, Y. Tang, Active power filter based on adaptive detecting approach of harmonic currents. J. Electromagn. Anal. Appl. 1, 240鈥?44 (2009)
  • 刊物主题:Communications Engineering, Networks;
  • 出版者:Springer India
  • ISSN:2250-2114
文摘
This paper presents a grid interfaced solar photovoltaic (SPV) energy system with a novel adaptive harmonic detection control for power quality improvement at ac mains under balanced as well as unbalanced and distorted supply conditions. The SPV energy system is capable of compensation of linear and nonlinear loads with the objectives of load balancing, harmonics elimination, power factor correction and terminal voltage regulation. The proposed control increases the utilization of PV infrastructure and brings down its effective cost due to its other benefits. The adaptive harmonic detection control algorithm is used to detect the fundamental active power component of load currents which are subsequently used for reference source currents estimation. An instantaneous symmetrical component theory is used to obtain instantaneous positive sequence point of common coupling (PCC) voltages which are used to derive inphase and quadrature phase voltage templates. The proposed grid interfaced PV energy system is modelled and simulated in MATLAB Simulink and its performance is verified under various operating conditions.
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083
For exchange or info please contact us via email.