Intraoperative graft assessment during coronary artery bypass surgery
详细信息    查看全文
  • 作者:Toshihiro Fukui (1)

    1. Department of Cardiovascular Surgery
    ; Sakakibara Heart Institute ; 3-16-1 Asahi-cho ; Fuchu ; Tokyo ; 183-0003 ; Japan
  • 关键词:Coronary artery bypass grafting ; Graft patency ; Intraoperative fluorescence imaging ; Transit ; time flow measurement
  • 刊名:General Thoracic and Cardiovascular Surgery
  • 出版年:2015
  • 出版时间:March 2015
  • 年:2015
  • 卷:63
  • 期:3
  • 页码:123-130
  • 全文大小:767 KB
  • 参考文献:1. Balacumaraswami, L, Taggart, DP (2004) Digital tools to facilitate intraoperative coronary artery bypass graft patency assessment. Semin Thorac Cardiovasc Surg 16: pp. 266-271 4.08.014" target="_blank" title="It opens in new window">CrossRef
    2. Balacumaraswami, L, Taggart, DP (2007) Intraoperative imaging techniques to assess coronary artery bypass graft patency. Ann Thorac Surg 83: pp. 2251-2257 CrossRef
    3. Mack, MJ (2008) Intraoperative coronary graft assessment. Curr Opin Cardiol 23: pp. 568-572 CrossRef
    4. Leacche, M, Balaguer, JM, Byrne, JG (2009) Intraoperative grafts assessment. Semin Thorac Cardiovasc Surg 21: pp. 207-212 CrossRef
    5. D鈥橝ncona, G, Bartolozzi, F, Bogers, AJ, Pilato, M, Parrinello, M, Kappetein, AP (2009) Intraoperative graft patency verification in coronary artery surgery: modern diagnostic tools. J Cardiothorac Vasc Anesth 23: pp. 232-238 CrossRef
    6. Yamamoto, M, Sasaguri, S, Sato, T (2011) Assessing intraoperative blood flow in cardiovascular surgery. Surg Today 41: pp. 1467-1474 4553-0" target="_blank" title="It opens in new window">CrossRef
    7. Magee, MJ, Alexander, JH, Hafley, G, Ferguson, TB, Gibson, CM, Harrington, RA (2008) PREVENT IV Investigators. Coronary artery bypass graft failure after on-pump and off-pump coronary artery bypass: findings from PREVENT IV. Ann Thorac Surg 85: pp. 494-499 CrossRef
    8. Yau, JM, Alexander, JH, Hafley, G, Mahaffey, KW, Mack, MJ, Kouchoukos, N (2008) PREVENT IV Investigators. Impact of perioperative myocardial infarction on angiographic and clinical outcomes following coronary artery bypass grafting (from PRoject of Ex-vivo Vein graft ENgineering via Transfection [PREVENT] IV). Am J Cardiol 102: pp. 546-551 4.069" target="_blank" title="It opens in new window">CrossRef
    9. Fukui, T, Tabata, M, Manabe, S, Shimokawa, T, Takanashi, S (2010) Graft selection and one-year patency rates in patients undergoing coronary artery bypass grafting. Ann Thorac Surg 89: pp. 1901-1905 CrossRef
    10. D鈥橝ncona, G, Karamanoukian, HL, Ricci, M, Schmid, S, Bergsland, J, Salerno, TA (2000) Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting. Eur J Cardiothorac Surg 17: pp. 287-293 40(00)00332-8" target="_blank" title="It opens in new window">CrossRef
    11. Hattler, B, Messenger, JC, Shroyer, AL, Collins, JF, Haugen, SJ, Garcia, JA (2012) Veterans Affairs Randomized On/Off Bypass (ROOBY) Study Group. Off-Pump coronary artery bypass surgery is associated with worse arterial and saphenous vein graft patency and less effective revascularization: results from the Veterans Affairs Randomized On/Off Bypass (ROOBY) trial. Circulation 125: pp. 2827-2835 CrossRef
    12. Takami, Y, Ina, H (2001) Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting. Ann Thorac Surg 72: pp. 1270-1274 4975(01)02933-2" target="_blank" title="It opens in new window">CrossRef
    13. Takami, Y, Tajima, K, Terazawa, S, Okada, N, Fujii, K, Sakai, Y (2009) Transit-time flow characteristics of in situ right gastroepiploic arterial grafts in coronary artery bypass grafting. J Thorac Cardiovasc Surg 138: pp. 669-673 CrossRef
    14. Jakobsen, HL, Kjaergard, HK (1999) Severe impairment of graft flow without electrocardiographic changes during coronary artery bypass grafting. Scand Cardiovasc J. 33: pp. 157-159 4017439950141786" target="_blank" title="It opens in new window">CrossRef
    15. Kim, KB, Kang, CH, Lim, C (2005) Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts. Ann Thorac Surg 80: pp. 594-598 47" target="_blank" title="It opens in new window">CrossRef
    16. Giammarco, G, Pano, M, Cirmeni, S, Pelini, P, Vitolla, G, Mauro, M (2006) Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery. J Thorac Cardiovasc Surg 132: pp. 468-474 4" target="_blank" title="It opens in new window">CrossRef
    17. Tokuda, Y, Song, MH, Oshima, H, Usui, A, Ueda, Y (2008) Predicting midterm coronary artery bypass graft failure by intraoperative transit time flow measurement. Ann Thorac Surg 86: pp. 532-536 4.023" target="_blank" title="It opens in new window">CrossRef
    18. Hirotani, T, Kameda, T, Shirota, S, Nakao, Y (2001) An evaluation of the intraoperative transit time measurements of coronary bypass flow. Eur J Cardiothorac Surg 19: pp. 848-852 40(01)00700-X" target="_blank" title="It opens in new window">CrossRef
    19. Leong, DK, Ashok, V, Nishkantha, A, Shan, YH, Sim, EK (2005) Transit-time flow measurement is essential in coronary artery bypass grafting. Ann Thorac Surg 79: pp. 854-857 4.06.010" target="_blank" title="It opens in new window">CrossRef
    20. Hassanein, W, Albert, AA, Arnrich, B, Walter, J, Ennker, IC, Rosendahl, U (2005) Intraoperative transit time flow measurement: off-pump versus on-pump coronary artery bypass. Ann Thorac Surg 80: pp. 2155-2161 CrossRef
    21. Becit, N, Erkut, B, Ceviz, M, Unlu, Y, Colak, A, Kocak, H (2007) The impact of intraoperative transit time flow measurement on the results of on-pump coronary surgery. Eur J Cardiothorac Surg 32: pp. 313-318 4.037" target="_blank" title="It opens in new window">CrossRef
    22. Herman, C, Sullivan, JA, Buth, K, Legare, JF (2008) Intraoperative graft flow measurements during coronary artery bypass surgery predict in-hospital outcomes. Interact CardioVasc Thorac Surg 7: pp. 582-585 CrossRef
    23. Balacumaraswami, L, Abu-Omar, Y, Selvanayagam, J, Pigott, D, Taggart, DP (2008) The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio. J Thorac Cardiovasc Surg 135: pp. 533-539 CrossRef
    24. Kieser, TM, Rose, S, Kowalewski, R, Belenkie, I (2010) Transit-time flow predicts outcomes in coronary artery bypass graft patients: a series of 1000 consecutive arterial grafts. Eur J Cardiothorac Surg 38: pp. 155-162 CrossRef
    25. Giammarco, G, Rabozzi, R (2010) Can transit-time flow measurement improve graft patency and clinical outcome in patients undergoing coronary artery bypass grafting?. Interact CardioVasc Thorac Surg 11: pp. 635-640 CrossRef
    26. Jokinen, JJ, Werkkala, K, Vainikka, T, Per盲kyl盲, T, Simpanen, J, Ihlberg, L (2011) Clinical value of intra-operative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study. Eur J Cardiothorac Surg 39: pp. 918-923 CrossRef
    27. Yu, Y, Zhang, F, Gao, MX, Li, HT, Li, JX, Song, W (2013) The application of intraoperative transit time flow measurement to accurately assess anastomotic quality in sequential vein grafting. Interact CardioVasc Thorac Surg 17: pp. 938-943 CrossRef
    28. Une, D, Deb, S, Chikazawa, G, Kommaraju, K, Tsuneyoshi, H, Karkhanis, R (2013) Cut-off values for transit time flowmetry: are the revision criteria appropriate?. J Card Surg 28: pp. 3-7 CrossRef
    29. Nordgaard, H, Nordhaug, D, Kirkeby-Garstad, I, L酶vstakken, L, Vitale, N, Haaverstad, R (2009) Different graft flow patterns due to competitive flow or stenosis in the coronary anastomosis assessed by transit-time flowmetry in a porcine model. Eur J Cardiothorac Surg 36: pp. 137-142 CrossRef
    30. D鈥橝ncona, G, Karamanoukian, HL, Bergsland, J (2001) Is intraoperative measurement of coronary blood flow a good predictor of graft patency?. Eur J Cardiothorac Surg 20: pp. 1075-1077 40(01)00937-X" target="_blank" title="It opens in new window">CrossRef
    31. Suematsu, Y, Takamoto, S, Ohtsuka, T (2001) Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. J Thorac Cardiovasc Surg 122: pp. 1147-1154 CrossRef
    32. Budde, RP, Meijer, R, Dessing, TC, Borst, C, Gr眉ndeman, PF (2005) Detection of construction errors in ex vivo coronary artery anastomoses by 13-MHz epicardial ultrasonography. J Thorac Cardiovasc Surg 129: pp. 1078-1083 4.09.002" target="_blank" title="It opens in new window">CrossRef
    33. Hol, PK, Andersen, K, Skulstad, H, Halvorsen, PS, Lingaas, PS, Andersen, R (2007) Epicardial ultrasonography: a potential method for intraoperative quality assessment of coronary bypass anastomoses?. Ann Thorac Surg 84: pp. 801-807 4.025" target="_blank" title="It opens in new window">CrossRef
    34. Eikelaar, JH, Meijer, R, Boven, WJ, Klein, P, Gr眉ndeman, PF, Borst, C (2002) Epicardial 10-MHz ultrasound in off-pump coronary bypass surgery: a clinical feasibility study using a minitransducer. J Thorac Cardiovasc Surg 124: pp. 785-789 CrossRef
    35. Budde, RP, Bakker, PF, Gr眉ndeman, PF, Borst, C (2009) High-frequency epicardial ultrasound: review of a multipurpose intraoperative tool for coronary surgery. Surg Endosc 23: pp. 467-476 464-008-0082-y" target="_blank" title="It opens in new window">CrossRef
    36. Orihashi, K, Sueda, T, Okada, K, Imai, K (2005) Left internal thoracic artery graft assessed by means of intraoperative transesophageal echocardiography. Ann Thorac Surg 79: pp. 580-584 4.07.014" target="_blank" title="It opens in new window">CrossRef
    37. Orihashi, K, Okada, K, Imai, K, Kurosaki, T, Takasaki, T, Takahashi, S (2009) Intraoperative assessment of coronary bypass graft to posterior descending artery by means of transesophageal echocardiography. Interact CardioVasc Thorac Surg 8: pp. 507-511 CrossRef
    38. Kuroda, M, Hamada, H, Kawamoto, M, Orihashi, K, Sueda, T, Otsuka, M (2009) Assessment of internal thoracic artery patency with transesophageal echocardiography during coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth 23: pp. 822-827 CrossRef
    39. Hol, PK, Lingaas, PS, Lundblad, R, Rein, KA, Vatne, K, Smith, HJ (2004) Intraoperative angiography leads to graft revision in coronary artery bypass surgery. Ann Thorac Surg 78: pp. 502-505 4.03.004" target="_blank" title="It opens in new window">CrossRef
    40. Aydin, U, Aydin, N, Gorur, A, Findik, O, Duzyol, C, Yilmaz, M (2013) Cineangiographic intraoperative evaluation of venous grafts during coronary bypass surgery. J Card Surg 28: pp. 258-261 4" target="_blank" title="It opens in new window">CrossRef
    41. Zhao, DX, Leacche, M, Balaguer, JM, Boudoulas, KD, Damp, JA, Greelish, JP (2009) Routine intraoperative completion angiography after coronary artery bypass grafting and 1-stop hybrid revascularization results from a fully integrated hybrid catheterization laboratory/operating room. J Am Coll Cardiol 53: pp. 232-241 CrossRef
    42. Mack, MJ, Magovern, JA, Acuff, TA, Landreneau, RJ, Tennison, DM, Tinnerman, EJ (1999) Results of graft patency by immediate angiography in minimally invasive coronary artery surgery. Ann Thorac Surg 68: pp. 383-389 4975(99)00648-7" target="_blank" title="It opens in new window">CrossRef
    43. Taggart, DP, Choudhary, B, Anastasiadis, K, Abu-Omar, Y, Balacumaraswami, L, Pigott, DW (2003) Preliminary experience with a novel intraoperative fluorescence imaging technique to evaluate the patency of bypass grafts in total arterial revascularization. Ann Thorac Surg 75: pp. 870-873 4975(02)04669-6" target="_blank" title="It opens in new window">CrossRef
    44. Balacumaraswami, L, Abu-Omar, Y, Anastasiadis, K, Choudhary, B, Pigott, D, Yeong, SK (2004) Does off-pump total arterial grafting increase the incidence of intraoperative graft failure?. J Thorac Cardiovasc Surg 128: pp. 238-244 CrossRef
    45. Takahashi, M, Ishikawa, T, Higashidani, K, Katoh, H (2004) SPY: an innovative intra-operative imaging system to evaluate graft patency during off-pump coronary artery bypass grafting. Interact CardioVasc Thorac Surg 3: pp. 479-483 4.01.018" target="_blank" title="It opens in new window">CrossRef
    46. Balacumaraswami, L, Abu-Omar, Y, Choudhary, B, Pigott, D, Taggart, DP (2005) A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency. J Thorac Cardiovasc Surg 130: pp. 315-320 4.11.033" target="_blank" title="It opens in new window">CrossRef
    47. Desai, ND, Miwa, S, Kodama, D, Koyama, T, Cohen, G, Pelletier, MP (2006) A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts. J Thorac Cardiovasc Surg 132: pp. 585-594 CrossRef
    48. Waseda, K, Ako, J, Hasegawa, T, Shimada, Y, Ikeno, F, Ishikawa, T (2009) Intraoperative fluorescence imaging system for on-site assessment of off-pump coronary artery bypass graft. JACC Cardiovasc Imaging. 2: pp. 604-612 CrossRef
    49. Hatada, A, Okamura, Y, Kaneko, M, Hisaoka, T, Yamamoto, S, Hiramatsu, T (2011) Comparison of the waveforms of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency. Gen Thorac Cardiovasc Surg. 59: pp. 14-18 48-010-0611-1" target="_blank" title="It opens in new window">CrossRef
  • 刊物主题:Thoracic Surgery; Cardiac Surgery; Cardiology; Surgical Oncology;
  • 出版者:Springer Japan
  • ISSN:1863-6713
文摘
Coronary artery bypass grafting (CABG) is an established revascularization method for treating multivessel coronary artery disease. The goal of CABG is to achieve complete revascularization with a durable, patent graft without reintervention. However, early graft failure, including that associated with technical errors, has been reported. This makes intraoperative verification of graft patency one of the most important ways in which surgeons can reduce the rate of early graft failure. Conventional angiography is considered the gold standard for graft assessment. However, because it is invasive and inconvenient, several alternatives to intraoperative graft assessment have become available that help reduce early graft failure by allowing revision of the anastomosis intraoperatively. The aim of this article is to review the advantages and disadvantages of several intraoperative graft assessment methods for CABG.
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083
For exchange or info please contact us via email.