Carbon nanotube-ionic liquid nanocomposite modified carbon-ceramic electrode for determination of dopamine in real samples
- 作者:Mir Reza Majidi (1251)
Reza Fadakar Bajeh Baj (1251) Abdolhossein Naseri (1251)
- 关键词:Multi walled carbon nanotubes ; Ionic liquid ; Nanocomposite ; Dopamine ; Carbon ; ceramic electrode
- 刊名:Central European Journal of Chemistry
- 出版年:2013
- 出版时间:July 2013
- 年:2013
- 卷:11
- 期:7
- 页码:1172-1186
- 全文大小:2934KB
- 参考文献:1. J. Zhang, X. Tan, D. Zhao, S. Tan, Z. Huang, Y. Mi, Z. Huang, Electrochim. Acta 55, 2522 (2010) CrossRef
2. M. Valcarcel, B.M. Simonet, S. Cardenas, B. Suarez, Anal. Bioanal. Chem. 382, 1783 (2005) CrossRef 3. B. Rezaei, S. Damiri, Electroanalysis 21, 1577 (2009) CrossRef 4. J. Tashkhourian, M.R. Hormozi Nezhad, J. Khodavesi, S. Javadi, J. Electroanal. Chem. 633, 85 (2009) CrossRef 5. M. Mmazloum-Ardakani, H. Beitollahi, B. Ganjipour, H. Naeimi, M. Nejati, Bioelectrochem.75, 1 (2009) CrossRef 6. Z. Zhua, X. Li, Y. Wang, Y. Zeng, W. Sun, X. Huang, Anal. Chim. Acta 670, 51 (2010) CrossRef 7. W. Sun, Q. Jiang, Y. Wang, K. Jiao, Sens. Actuat. B 136, 419 (2009) CrossRef 8. M. Bahram, K. Farhadi, F. Arjmand, Cent. Eur. J. Chem. 7, 524 (2009) CrossRef 9. H.M. Huang, C.H. Lin, J. Chromatogr. B 816, 113 (2005) CrossRef 10. M. Maminski, M. Olejniczak, M. Chudy, A. Dybko, Z. Brzózka, Anal. Chim. Acta 540,153 (2005) CrossRef 11. P. Uutela, R. Reinila, K. Harju, P. Piepponen, R.A. Ketola, R. Kostiainen, Anal. Chem. 81, 8417 (2009) CrossRef 12. W.A. El-Said, J-H. Lee, B-K. Oh, J-W. Choi, Electrochem. Commun. 12, 1756 (2010) CrossRef 13. M.R. Majidi, K. Asadpour-Zeynali, S. Gholizadeh, Electroanlysis 22, 1772 (2010) CrossRef 14. H-S. Guo, X-W. He,Y-J. Li, Chin. J. Chem. 21, 1624 (2003) CrossRef 15. W. Chen, X. Lin, L. Huang, H. Luo, Microchim. Acta 151, 101 (2005) CrossRef 16. A. Stoyanova, S. Ivanov, V. Tsakova, A. Bund, Eelectrochim. Acta 56, 3693 (2011) CrossRef 17. S. Hou, N. Zheng, H. Feng, X. Li, Z. Yuan, Anal. Biochem. 179, 179 (2008) CrossRef 18. Z. Zhu, L. Qu, Y. Guo, Y. Zeng, W. Sun, X. Huang, Sens. Actuat. B 151, 146 (2010) CrossRef 19. K. Wu, S. Hu, Microchim. Acta 144, 131 (2004) CrossRef 20. R.C. Carvalho, C. Gouveia-Caridade, C.M.A. Brett, Anal. Bioanal. Chem. 98, 1675 (2010) CrossRef 21. K. Wu, J. Fei, S. Hu, Anal. Biochem. 318, 100 (2003) CrossRef 22. Z.A. Lothmana, N. Bukharia, S.M. Wabaidura, S. Haiderb, Sens. Actuat. B 146, 314 (2010) CrossRef 23. A. Liu, I. Honma, H. Zhou, Biosens. Bioelectron. 23, 74 (2007) CrossRef 24. M. Zhang, K. Gong, H. Zhang, L. Mao, Biosens. Bioelectron. 20, 127 (2005) CrossRef 25. E. Baldricha, R. Gómeza, G. Gabriela, F. Xavier M?noza, Biosens. Bioelectron. 26, 1876 (2011). CrossRef 26. R. Cuia, X. Wang, G. Zhang, C. Wang, Sens. Actuat. B 161,1139 (2012) CrossRef 27. X. Liu, Y. Peng, X. Qu, S. Ai, R. Han, X. Zhu, J. Electroanal. Chem. 654, 72 (2011) CrossRef 28. R. Manjunatha, G. Shivappa Suresh, J. Savio Melo, S.F. D’Souza, T. Venkatarangaiah Venkatesha, Sens. Actuat. B 145, 643 (2010) CrossRef 29. D.P. Quan, D.P. Tuyen, T. Dai Lam, P.T. Ngoc Trama, N. Hai Binh, P. Hung Vieta, Colloids Surf. B: Bioint. 88, 764 (2011) CrossRef 30. W. Sun, M. Yang, K. Jiao, Anal. Bioanal. Chem. 389, 1283 (2007) CrossRef 31. J. Dong, Y. Hu, S. Zhu, J. Xu, Y. Xu, Anal. Bioanal. Chem. 396, 1755 (2010) CrossRef 32. J. Ping, J. Wu, Y. Ying, Electrochem. Commun. 12, 1783 (2010) CrossRef 33. D.V. Chrnyshov, N.V. Shvedene, E.R. Antipova, I.V Pletnev, Anal. Chim. Acta 621, 178 (2008) CrossRef 34. A. Safavi, N. Maleki, O. Moradlou, F. Tajabadi, Anal. Biochem. 359, 224 (2006) CrossRef 35. Y. Li, X. Liu, X. Zeng, X. Liu, B. Kong, W. Wei, S. Luo, Electrochim. Acta 56, 2730 (2011) CrossRef 36. J-L. Chang, G-T. Wei, J-M. Zen, Electrochem. Commun. 13, 174 (2011) CrossRef 37. M. Pandurangachar, B.E. Kumara Swamy, B.N. Chandrashekar, O. Gilbert, B. S. Sherigara, J. Mol. Liq. 158,13 (2011) CrossRef 38. T. Fukushima, A. Kosaka, Y. Lshimura, T. Yamamoto, T. Takigawa, N. Ishii, T. Aida, Science 300, 2072 (2003) CrossRef 39. Y. Zhao, Y. Gao, D. Zhan, H. Liu, Q. Zhao, Y. Kou, Y. Shao, M. Li, Q. Zhuang, Z. Zhu, Talanta 66, 1 (2009) 40. Y. Sun, J. Fei, J. Hou, Q. Zhang, Y. Liu, B. Hu, Microchim. Acta 165,373 (2009) CrossRef 41. S. Yong Ha, S. Kim, J. Electroanal. Chem. 468, 131 (1999) CrossRef 42. L. Rabinovich, O. Lev, Electroanalysis 13, 265 (2001) CrossRef 43. M. Opallo, M. Saczek-Maj, Electrochem. Commun. 3, 306 (2001) CrossRef 44. T. Zhan, X. Sun, X. Wang, W. Sun, W. Hou, Talanta 82, 1853 (2010) CrossRef 45. A. Salimi, M. Roushani, B. Haghighi, S. Soltanian, Biosens. Bioelectron. 22, 220 (2006) CrossRef 46. P. Wang, Y. Yuan, G. Zhu, J. Electroanal. Chem. 519, 130 (2002) CrossRef 47. A. Abbaspour, A. Khajehzadeh, A. Ghaffarinejad, J. Electroanal. Chem. 631, 52 (2009) CrossRef 48. B.B. Prasad, D. Kumar, R. Madhuri, M. P. Tiwari, Electrochim. Acta 56, 7202 (2011) CrossRef 49. E.J. Laviron, J. Electroanal. Chem 101, 19 (1979) CrossRef 50. W. Sun, Y. Li, M. Yang, J. Li, K. Jiao, Sens. Actuat. B 133, 387 (2008) CrossRef 51. A.S. Adekunle, B.O. Agboola, J. Pillay, K.I. Ozoemena, Sens. Actuat. B 148, 93 (2010) CrossRef 52. N. Nasirizadeh, Z. Shekari, H. R. Zare, S. Makarem, Mat. Sci. Eng. C 33, 1491 (2013) CrossRef
- 作者单位:Mir Reza Majidi (1251)
Reza Fadakar Bajeh Baj (1251) Abdolhossein Naseri (1251)
1251. Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, 51664, Iran
- ISSN:1644-3624
文摘
Room temperature 1-butyl-3-methylimidazolium tetraflouroborate ([BMIM][BF4]) ionic liquid was employed for dispersion of multi walled carbon nanotubes (MWCNTs) and the formation of nanocomposite on the surface of a carbon-ceramic electrode. The surface of the modified electrode was characterized using scanning electron microscopy and electrochemical impedance spectroscopy. The modified electrode exhibited excellent electrochemical activity to oxidation of dopamine (DA); whereas electro oxidation of ascorbic acid (AA) was not seen and electro oxidation of uric acid (UA) appeared at a more positive potential than DA. The multi walled carbon nanotube-ionic liquid nanocomposite modified carbon-ceramic electrode was used for the selective determination of DA in the presence of high levels of AA and UA using differential pulse voltammetry. The calibration curve for DA was linear in the range of 3.00 to 130 μM with the detection limit (S/N=3) of 0.87 μM. The present electrode was successfully applied to the determination of DA in some commercial pharmaceutical samples and human blood serum.
| |