Stability evaluation and correction of a pulsed neutron generator prompt gamma activation analysis system
详细信息    查看全文
  • 作者:Roman J. Shypailo
  • 关键词:Body composition ; Neutron activation analysis ; Nitrogen ; Humans ; Neutron generator
  • 刊名:Journal of Radioanalytical and Nuclear Chemistry
  • 出版年:2016
  • 出版时间:March 2016
  • 年:2016
  • 卷:307
  • 期:3
  • 页码:1781-1786
  • 全文大小:636 KB
  • 参考文献:1.Barzilov AP, Novikov IS, Womble PC (2012) Gamma radiation. In: Adrovic F (ed.). InTech Open Access Publisher [eBooks]. http://​www.​healthwise.​org . Accessed 24 Feb 2014
    2.Nagai T, Fujii I, Muto H, Inouye T (1969) Total-body nitrogen and protein determined by in vivo fast-neutron activation analysis. J Nucl Med 10:192–196
    3.Gierlik M, Batsch T, Moszynski M, Szczesniak T, Wolski D, Klamra W, Perot B, Perret G (2006) Comparative study of large NaI(Tl) and BGO scintillators for the EURopean illicit TRAfficking countermeasures kit project. IEEE Trans Nucl Sci 53:1737–1743CrossRef
    4.Gordon CM, Peters CW (1990) A fast-neutron probe for tomography and bulk analysis. Intern J Appl Radiat Isot 41:1111–1116CrossRef
    5.Vourvopoulos G, Womble PC (2001) Pulsed fast/thermal neutron analysis: a technique for explosives detection. Talanta 54(3):459–468CrossRef
    6.Litz M, Waits C, Mullins J (2012) Neutron-activated gamma-emission: technology review, ARL-TR-5871. Army Research Lab, Adelphi
    7.Shypailo RJ, Workeneh B, Ellis KJ (2013) Assessment of the associated particle prompt gamma neutron activation technique for total body nitrogen measurement in vivo. J Radioanal Nucl Chem 296:143–148
    8.Beddoe AH, Zuidmeer A, Hill GL (1984) A prompt gamma in vivo neutron activation analysis facility for measurement of total body nitrogen in the critically ill. Phys Med Biol 29:371–383CrossRef
    9.Chichester DL, Simpson JD, Lemchak M (2007) Advanced compact accelerator neutron generator technology for active neutron interrogation field work. J Radioanal Nucl Chem 271:629–637CrossRef
    10.Reijonen J, Gicquel F, Hahto SK, King M, Lou TP, Leung KN (2005) D-D neutron generator development at LBNL. Appl Radiat Isot 63:757–763CrossRef
    11.Fantidis JG, Nicolaou GE, Potolias C, Vordos N, Bandekas DV (2011) The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron. J Radioanal Nucl Chem 290:289–295CrossRef
    12.Danon Y (2012) Pyroelectric crystal D-D and D-T neutron generators. J Instrum 7(4):C04002. doi:10.​1088/​1748-0221/​7/​04/​C04002 CrossRef
    13.Gillich D, Kovanen A, Herman B, Fullem T, Danon Y (2009) Pyroelectric crystal neutron production in a portable prototype vacuum system. Nucl Instrum Methods Phys Res Sect A 602:306–310CrossRef
    14.Kramer GH, Burns LC, Noel L (1991) The BRMD BOMAB phantom family. Health Phys 61:895–902CrossRef
    15.Russo P, Vo D (2005) Gamma-ray detectors for nondestructive analysis. Los Alamos National Laboratory. Report LA-UR-05-3813
  • 作者单位:Roman J. Shypailo (1)

    1. Department of Pediatrics, USDA/ARS Children’s Nutrition Research Center, Baylor College of Medicine, 1100 Bates Street, Houston, TX, 77030, USA
  • 刊物类别:Chemistry and Materials Science
  • 刊物主题:Chemistry
    Nuclear Chemistry
    Physical Chemistry
    Nuclear Physics, Heavy Ions and Hadrons
    Diagnostic Radiology
    Inorganic Chemistry
  • 出版者:Akad茅miai Kiad贸, co-published with Springer Science+Business Media B.V., Formerly Kluwer Academic
  • ISSN:1588-2780
文摘
Source output stability is important for accurate measurement in prompt gamma neutron activation. This is especially true when measuring low-concentration elements such as in vivo nitrogen (~2.5 % of body weight). We evaluated the stability of the compact DT neutron generator within an in vivo nitrogen measurement system. Review of gamma event/time patterns and data from an auxiliary detector showed significant variations among repeated phantom runs. Neutron generator instability had a significant effect on measurement precision. The neutron generator used in our system must be monitored for output consistency. Adjustments must be made to measurement results to correct for generator instability.
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083
For exchange or info please contact us via email.