Confocal stereology: an efficient tool for measurement of microscopic structures
详细信息    查看全文
  • 作者:Lucie Kubínová ; Ji?í Janá?ek
  • 关键词:3 ; D images ; Confocal microscopy ; Geometrical characteristics ; Spatial probes ; Stereology
  • 刊名:Cell and Tissue Research
  • 出版年:2015
  • 出版时间:April 2015
  • 年:2015
  • 卷:360
  • 期:1
  • 页码:13-28
  • 全文大小:2,018 KB
  • 参考文献:1. Albrechtová, J, Janá?ek, J, Lhotáková, Z, Radochová, R, Kubínová, L (2007) Novel efficient methods for measuring mesophyll anatomical characteristics from fresh thick sections using stereology and confocal microscopy: application on acid rain-treated Norway spruce needles. J Exp Bot 58: pp. 1451-1461
    2. ?slund N, Carlsson K, Liljeborg A, Majlof L (1983) PHOIBOS, a microscope scanner designed for micro-fluorometric applications, using laser induced fluorescence. In: Proceedings of the Third Scandinavian Conference on Image Analysis. Studentliteratur, Lund
    3. Baddeley, AJ, Gundersen, HJG, Cruz-Orive, LM (1986) Estimation of surface area from vertical sections. J Microsc 142: pp. 259-276
    4. Bandaru, V, Hansen, DJ, Codling, EE, Daughtry, CS, White-Hansen, S, Green, CE (2010) Quantifying arsenic-induced morphological changes in spinach leaves: implications for remote sensing. Int J Remote Sens 31: pp. 4163-4177
    5. Baquet, ZC, Williams, D, Brody, J, Smeyne, RJ (2009) A comparison of model-based (2D) and design-based (3D) stereological methods for estimating cell number in the substantia nigra pars compacta (SNpc) of the C57BL/6J mouse. Neuroscience 161: pp. 1082-1090
    6. Bauer, J, Bahmer, FA, W?rl, J, Neuhuber, W, Schuler, G, Fartasch, M (2001) A strikingly constant ratio exists between Langerhans cells and other epidermal cells in human skin. A stereologic study using the optical disector method and the confocal laser scanning microscope. J Investig Dermatol 116: pp. 313-318
    7. Bjaalije, JG (2002) Localization in the brain: new solutions emerging. Nat Rev Neurosci 3: pp. 322-325
    8. Burdíková, Z, ?apek, M, Osta?ov, P, Macha?, J, Pelc, R, Mitchell, EAD, Kubínová, L (2010) Testate amoebae examined by confocal and two-photon microscopy: implications for taxonomy and ecophysiology. Microsc Microanal 16: pp. 735-746
    9. ?apek, M, Janá?ek, J, Kubínová, L (2006) Methods for compensation of the light attenuation with depth of images captured by a confocal microscope. Microsc Res Tech 69: pp. 624-635
    10. ?eba?ek, V, Kubínová, L, Ribari?, S, Er?en, I (2004) A novel staining method for quantification and 3D visualisation of capillaries and muscle fibres. Eur J Histochem 48: pp. 151-158
    11. ?eba?ek, V, Kubínová, L, Ribari?, S, Er?en, I (2005) Capillary network in slow and fast muscles and in oxidative and glycolitic muscle fibres. Image Anal Stereol 24: pp. 51-58
    12. ?eba?ek, V, Radochová, R, Ribari?, S, Kubínová, L, Er?en, I (2006) Nerve injury affects the capillary supply in rat slow and fast muscles differently. Cell Tissue Res 323: pp. 305-312
    13. ?eba?ek, V, Kubínová, L, Janá?ek, J, Ribari?, S, Er?en, I (2007) Adaptation of muscle fibre types and capillary network to acute denervation and shortlasting reinnervation. Cell Tissue Res 330: pp. 279-289
    14. ?eba?ek, V, Er?en, I, Vyhnal, A, Janá?ek, J, Ribari?, S, Kubínová, L (2010) The estimation error of skeletal muscle capillary supply is significantly reduced by 3D method. Microvasc Res 79: pp. 40-46
    15. Cruz-Orive, LM (1989) On the precision of systematic sampling: a review of Matheron’s transitive methods. J Microsc 153: pp. 315-333
    16. Cruz-Orive LM (1993) Systematic sampling in stereology. Bull Intern Statis Inst Proceedings 49th Session, Florence 1993, 55: 451-68
    17. Cruz-Orive, LM (1997) Stereology of single objects. J Microsc 186: pp. 93-107
    18. Cruz-Orive, LM (1999) Precision of Cavalieri sections and slices with local errors. J Microsc 193: pp. 182-198
    19. Cruz-Orive, LM, Howard, CV (1991) Estimating the length of a bounded curve in three dimensions using total vertical projections. J Microsc 163: pp. 101-113
    20. Cruz-Orive, LM, Howard, CV (1995) Estimation of individual feature surface area with the vertical spatial grid. J Microsc 178: pp. 146-151
    21. Delorme, R, Benchaib, M, Bryon, PA, Souchier, C (1998) Measurement accuracy in confocal microscopy. J Microsc 192: pp. 151-162
    22. Denk, W, Strickler, JH, Webb, WW (1990) Two-photon laser scanning fluorescence microscopy. Science 248: pp. 73-76
    Diaspro, A eds. (2002) Confocal and two-photon microscopy. Wiley-Liss, New York
    23. Difato, F, Mazzone, F, Scaglione, S, Fato, M, Beltrame, F, Kubínová, L, Janá?ek, J, Ramoino, P, Vicidomini, G, Diaspro, A (2004) Improvement in volume estimation from confocal sections after image deconvolution. Microsc Res Tech 64: pp. 151-155
    24. Dorph-Petersen, KA, Nyengaard, JR, Gundersen, HJG (2001) Tissue shrinkage and unbiased stereological estimation of particle number and size. J Microsc 204: pp. 232-246
    25. Dvo?ák, J, Jensen, EBV (2013) On semiautomatic estimation of surface area. J Microsc 250: pp. 142-157
    26. Er?en, I, Janá?ek, J, Kubínová, L (2011) Characterisation of the capillary network in skeletal muscles from 3D data—a review. Physiol Res 60: pp. 1-13
    27. Everall, IP, Heaton, RK, Marcotte, TD, Ellis, RJ, McCutchan, JA
  • 刊物类别:Biomedical and Life Sciences
  • 刊物主题:Biomedicine
    Human Genetics
    Proteomics
    Molecular Medicine
  • 出版者:Springer Berlin / Heidelberg
  • ISSN:1432-0878
文摘
Quantitative measurements of geometric forms or counting of objects in microscopic specimens is an essential tool in studies of microstructure. Confocal stereology represents a contemporary approach to the evaluation of microscopic structures by using a combination of stereological methods and confocal microscopy. 3-D images acquired by confocal microscopy can be used for the estimation of geometrical characteristics of microscopic structures by stereological methods, based on the evaluation of optical sections within a thick slice and using computer-generated virtual test probes. Such methods can be used for estimating volume, number, surface area and length using relevant spatial probes, which are generated by specific software. The interactions of the probes with the structure under study are interactively evaluated. An overview of the methods of confocal stereology developed during the past 30?years is presented. Their advantages and pitfalls in comparison with other methods for measurement of geometrical characteristics of microscopic structures are discussed.
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083
For exchange or info please contact us via email.