Influence of respiratory motion correction on quantification of myocardial perfusion SPECT
详细信息    查看全文
  • 作者:Ahmad Bitarafan-Rajabi PhD ; Hossein Rajabi MD…
  • 关键词:99mTc ; tetrofosmin ; myocardial perfusion ; gated SPECT ; respiratory correction
  • 刊名:Journal of Nuclear Cardiology
  • 出版年:2015
  • 出版时间:October 2015
  • 年:2015
  • 卷:22
  • 期:5
  • 页码:1019-1030
  • 全文大小:2,287 KB
  • 参考文献:1.Germano G, Erel J, Kiat H, Kavanagh PB, Berman DS. Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT. J Nucl Med 1997;38:749-54.PubMed
    2.Go V, Bhatt MR, Hendel RC. The diagnostic and prognostic value of ECG-gated SPECT myocardial perfusion imaging. J Nucl Med 2004;45:912-21.PubMed
    3.Segars W, Sturgeon G, Mendonca S, Grimes J, Tsui B. 4D XCAT phantom for multimodality imaging research. Med Phys 2010;37:4902-15.PubMed Central CrossRef PubMed
    4.Redgate S, Barber DC, Abdallah A-M, Wendy TB. Using a registration-based motion correction algorithm to correct for respiratory motion during myocardial perfusion imaging. Nucl Med Commun 2013;34:787-95.CrossRef PubMed
    5.Pretorius PH, King MA, Tsui BM, LaCroix KJ, Xia W. A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging. Med Phys 1999;26:2323-32.CrossRef PubMed
    6.Reutter BW, Klein GJ, Huesman RH. Automated 3-D segmentation of respiratory-gated PET transmission images. IEEE Trans Nucl Sci 1997;44:2473-6.CrossRef
    7.McClelland J, Hawkes DJ, Schaeffter T, King AP. Respiratory motion models: A review. Med Image Anal 2013;17:19-42.CrossRef PubMed
    8.Pitman AG, Kalff V, Van Every B, Risa B, Barnden LR, Kelly MJ. Effect of mechanically simulated diaphragmatic respiratory motion on myocardial SPECT processed with and whitout attenuation correction. J Nucl Med 2002;43:1259-67.PubMed
    9.Vedam SS, Keall PJ, Kini VR, Mostafavi H, Shukla HP, Mohan R. Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol 2003;48:45-62.CrossRef PubMed
    10.Fredrickson JO, Wegmuller H, Herfkens RJ, Pelc NJ. Simultaneous temporal resolution of cardiac and respiratory motion in MR imaging. Radiology 1995;195:169-75.CrossRef PubMed
    11.Rahmim A, Tang J, Zaidi H. Four-dimensional image reconstruction strategies in cardiac-gated and respiratory-gated PET imaging. PET Clin 2013;8:51-67.CrossRef
    12.Polycarpou I, Tsoumpas C, King AP, Marsden PK. Impact of respiratory motion correction and spatial resolution on lesion detection in PET: A simulation study based on real MR dynamic data. Phys Med Biol 2014;59:697.CrossRef PubMed
    13.P茅pin A, Daouk J, Bailly P, Hapdey S, Meyer M-E. Management of respiratory motion in PET/computed tomography: The state of the art. Nucl Med Commun 2014;35:113.PubMed Central CrossRef PubMed
    14.Darwesh RM, Shin E, Morgan PS, Perkins AC. Improved visualization of perfusion defects by respiratory-gated SPECT: A phantom simulation study. Nucl Med Commun 2014;35:189-96.CrossRef PubMed
    15.Sakaguchi K, Hosono M, Otsuka M, Hanaoka K, Usami K, Uto T, et al. Dynamic sequence respiratory gated perfusion pulmonary SPECT without external tracking device. Ann Nucl Med 2013;27:65-73.CrossRef PubMed
    16.Kovalski G, Israel O, Keidar Z, Frenkel A, Sachs J, Azhari H. Correction of heart motion due to respiration in clinical myocardial perfusion SPECT scans using respiratory gating. J Nucl Med 2007;48:630-6.CrossRef PubMed
    17.Beach RD, Pretorius PH, Boening G, Bruyant P, Feng B, Fulton R, et al. Feasibility of stereo-infrared tracking to monitor patient motion during cardiac SPECT imaging. IEEE Trans Nucl Sci 2004;51:2693-8.PubMed Central CrossRef PubMed
    18.Livieratos L, Stegger L, Bloomfield PM, Schafers K, Bailey DL, Camici PG. Rigid body transformation of list-mode projection data for respiratory motion correction in cardiac PET. Phys Med Biol 2005;50:3313-22.CrossRef PubMed
    19.Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;8:307-10.CrossRef
    20.Cho K, Kumiata S, Okada S, Kumazaki T. Development of respiratory gated myocardial SPECT system. J Nucl Cardiol 1999;6:20-8.CrossRef PubMed
    21.Vedam SS, Kini VR, Keall PJ, Ramakrishnan V, Mostafavi H, Mohan R. Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. Med Phys 2003;30:505-13.CrossRef PubMed
    22.Nehrke K, B枚rnert P, Manke D, B枚ck JC. Free
    eathing cardiac MR imaging: Study of implications of respiratory motion-initial results. Radiology 2001;220:810-5.CrossRef PubMed
    23.Pillay M, Cox PH, Sch枚nfeld DHW, Mathews S. Tc-99m tetrofosmin myocardial distribution 4 hours post injection. Int J Cardiovasc Imaging 1996;12:127-35.CrossRef
    24.Zaret BL, Beller GA. Clinical nuclear cardiology: State of the art and further directions. 4th ed. Philadelphia: Mosby, Inc.; 2010.
    25.Laarman G, Niemeyer MG, Van Der Wall EE, Verzijlbergen FJ, Bruschke AV, Ascoop CA. Dipyridamole thallium testing: Noncardiac side effects, cardiac effects, electrocardiographic changes and hemodynamic changes after dipyridamole infusion with or without exercise. Int J Cardiol 1988;20:231-8.CrossRef PubMed
    26.Botvinick EH, Dae MW. Dipyridamole perfusion scintigraphy. Semin Nucl Med 1991;21:242-65.CrossRef PubMed
    27.Lenz TL, Hilleman DE. Aggrenox: A fixed-dose combination of aspirin and dipyridamole. Ann Pharmacother 2000;34:1283-90.CrossRef PubMed
    28.Bruyant P, King MA, Pretorius PH. Correction of the respiratory motion of the heart by tracking of the center of mass of thresholded projections: A simulation study using the dynamic MCAT phantom. IEEE Trans Nucl Sci 2002;49:2159-66.CrossRef
    29.Slomka PJ, Nishina H, Abidov A, Hayes SW, Friedman JD, Berman DS, et al. Combined quantitative supine-prone myocardial perfusion SPECT improves detection of coronary artery disease and normalcy rates in women. J Nucl Cardiol 2007;14:44-52.CrossRef PubMed
    30.K枚nik A, Kikut J, Lew R, Johnson K, King MA. Comparison of methods of acquiring attenuation maps for cardiac SPECT in the presence of respiratory motion. J Nucl Cardiol 2013;20:1093-107.PubMed Central CrossRef PubMed
    31.Goetze S, Brown TL, Lavely WC, Zhang Z, Bengel FM. Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration. J Nucl Med 2007;48:1090-5.CrossRef PubMed
    32.Celler A, Dixon KL, Chang Z, Blinder S, Powe J, Harrop R. Problems created in attenuation-corrected SPECT images by artifacts in attenuation maps: A simulation study. J Nucl Med 2005;46:335-43.PubMed
    33.Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: Comparison of 4 software programs. J Nucl Med 2001;42:1571-8.PubMed
    34.Hansen CL, Goldstein RA, Berman DS, Churchwell KB, Cooke D, Corbett JR, et al. Myocardial perfusion and function single photon emission computed tomography. J Nucl Cardiol 2006;13:97-120.CrossRef
  • 作者单位:Ahmad Bitarafan-Rajabi PhD (1)
    Hossein Rajabi MD (2)
    Feridoon Rastgou MD (1)
    Hasan Firoozabady MD (1)
    Nahid Yaghoobi MD (1)
    Hadi Malek MD (1)
    Werner Langesteger MD (3)
    Mohsen Beheshti MD (3)

    1. Department of Nuclear Medicine, Rajaie Cardiovasular, Medical & Research Center, Iran University of Medical Sciences, Tehran, Iran
    2. Department of Medical Physics, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran
    3. Department of Nuclear Medicine & Endocrinology, St Vincent鈥檚 Hospital, PET - CT Center Linz, Seilerstaette 4, Linz, A-4020, Austria
  • 刊物主题:Cardiology; Nuclear Medicine; Imaging / Radiology;
  • 出版者:Springer US
  • ISSN:1532-6551
文摘
Background Respiratory-related cardiac motion could have considerable effects on myocardial perfusion imaging, leading to misinterpretation of the images. In this study, we examined the influence of respiratory correction on ECG-gated myocardial perfusion SPECT (RC-GSPECT) concerning regional myocardial perfusion and function.
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083
For exchange or info please contact us via email.