Measurements of the transverse resistance and eddy current losses in a cable-in-conduit conductor
详细信息    查看全文
  • 作者:V. E. Keilin ; I. A. Kovalev ; S. L. Kruglov ; S. A. Lelekhov…
  • 刊名:Technical Physics
  • 出版年:2015
  • 出版时间:November 2015
  • 年:2015
  • 卷:60
  • 期:11
  • 页码:1697-1704
  • 全文大小:1,346 KB
  • 参考文献:1.N. A. Chernoplekov, Superconducting Magnet Systems for Tokamaks (IzdAt, Moscow, 1997), p. 15.
    2.I. Anashkin, et al., At. Energy 57, 401 (1984).CrossRef
    3.V. Keilin, et al., IEEE Trans. Appl. Supercond. 12, 567 (2002).CrossRef
    4.M. Sugihara, Nucl. Fusion 47, 337 (2007).CrossRef ADS
    5.D. Bassette, IEEE Trans. Appl. Supercon. 16, 795 (2006).CrossRef
    6.S. Lelekhov, Cryogenics 46, 1 (2006).CrossRef ADS
    7.“Thermophysical properties of helium-4 from 2 to 1500 K with pressure up to 1000 atm,” NBS Tech. Note No. 631 (1972).
    8.G. V. Trokhachev, “Summary of formulas for calculation of screening and energy losses due to eddy currents in conductors with various geometric shapes,” Preprint No. P-B-0428 NIIEFA (NII Electrofiz. Apparat., Leningrad, 1973).
  • 作者单位:V. E. Keilin (1)
    I. A. Kovalev (1)
    S. L. Kruglov (1) (2)
    S. A. Lelekhov (3)
    A. A. Il’in (1)
    A. V. Naumov (1)
    V. I. Shcherbakov (1)
    K. A. Shutov (4)

    1. National Research Centre Kurchatov Institute, pl. Kurchatova 1, Moscow, 123182, Russia
    2. National Research Nuclear University MEPhI, Kashirskoe sh. 31, Moscow, 115409, Russia
    3. ITER Center, pl. Kurchatova 1, Moscow, 123182, Russia
    4. All-Russian Research and Development Cable Institute, sh. Entuziastov 5, Moscow, 111024, Russia
  • 刊物类别:Physics and Astronomy
  • 刊物主题:Physics
    Mechanics, Fluids and Thermodynamics
    Russian Library of Science
  • 出版者:MAIK Nauka/Interperiodica distributed exclusively by Springer Science+Business Media LLC.
  • ISSN:1090-6525
文摘
In the case of plasma current interruption in tokamaks, the conductor of toroidial field (TF) coils experiences the action of a pulsed decreasing magnetic field (PDMF) parallel to the conductor’s axis. To estimate the stability of a cable-in-conduit conductor against the PDMF, a new experimental method to study different types of losses is applied. This method exploits a high sensitivity of temperature and gas pressure to input energy in a closed volume. It allows one to measure hysteresis losses with a rather high accuracy (provided that the rate of change of the PDMF is low) and a sum of hysteresis losses and eddy current losses (when the rate of change of the PDMF is high). An experimental setup to measure the transverse (circumferential) resistance and losses has been developed at the National Research Centre Kurchatov Institute. A Russianmade Nb3Sn conductor intended for the TF coils of the International Thermonuclear Experimental Reactor is subjected to a PDMF with different amplitudes and characteristic times. The electromagnetic time constant and the transverse resistivity of the conductor are experimentally determined. The maximum temperature of strands under the action of the PDMF is calculated.