Waveguide-coupled bimetallic film for enhancing the sensitivity of a surface plasmon resonance sensor in a fixed-angle mode
详细信息    查看全文
  • 作者:Yeon Kyung Lee (1)
    Young-Soo Sohn (1)
    Kyeong-Seok Lee (2)
    Won Mok Kim (2)
    Jeong-Ok Lim (3)
  • 关键词:Waveguide ; coupled bimetallic chip ; Surface plasmon resonance sensor ; Fixed ; angle mode
  • 刊名:Journal of the Korean Physical Society
  • 出版年:2013
  • 出版时间:February 2013
  • 年:2013
  • 卷:62
  • 期:3
  • 页码:475-480
  • 全文大小:241KB
  • 参考文献:1. B. Bohunicky and S. A. Mousa, Nanotech. Sci. Appl. 4, 1 (2011).
    2. I. E. Tothill, Semin. Cell Dev. Biol. 20, 55 (2009). CrossRef
    3. R. J. H. Timothy, D. Frank and P. J. H. S鈥檈amus, Biosens. Bioelectron. 34, 12 (2012). CrossRef
    4. E. C. Robert, Anal. Chem. 81, 5972 (2009). CrossRef
    5. J. Zhang, S. Song, L. Zhang, L. Wang, H. Wu, D. Pan and C. Fan, J. Am. Chem. Soc. 128, 8575 (2006). CrossRef
    6. R. Cui, H. Huang, Z. Yin, D. Gao and J.-J. Zhu, Biosens. Bioelectron. 23, 1666 (2008). CrossRef
    7. S. S. Agasti, M. Liong, C. Tassa, H. J. Chung, S. Y. Shaw, H. Lee and R. Weissleder, Angew. Chem. Int. Ed. 51, 450 (2012). CrossRef
    8. S. Ray, G. Mehta and S. Srivastava, Proteomics 10, 731 (2010). CrossRef
    9. M. A. Cooper, / Label-free Biosensors: Techniques and Applications (Cambridge University Press, New York, 2008)
    10. Y.-S. Sohn, C.-K. Kim and S.-Y. Choi, Sens. Lett. 7, 640 (2009). CrossRef
    11. C. I. Cheng, Y. P. Chang and Y. H. Chu, Chem. Soc. Rev. 41, 1947 (2012). CrossRef
    12. N. Ioan, Sensors 7, 1343 (2007). CrossRef
    13. H. S铆pov谩, S. Zhang, A. M. Dudley, D. Galas, K. Wang and J. Homola, Anal. Chem. 82, 10110 (2010). CrossRef
    14. P. Englebienne, A. V. Hoonacker and M. Verhas, Spectroscopy 17, 255 (2003). CrossRef
    15. A. Ibrahim, Z. Mohammad and L. Akhlesh, Electromagnetics 28, 214 (2008). CrossRef
    16. H. Nakagawa, I. Saito, T. Chinzei, Y. Nakaoki and Y. Iwata, Sens. Actuators, B 108, 772 (2005). CrossRef
    17. A. Z. Stepan, V. S. Anton, R. S. Elena, M. M. Vladimir and M. S. Yuri, Sensors 2, 62 (2002).
    18. Y. Wan, Z. Zheng, A. Lu, J. Liu and J. Zhu, Sens. Actuators, B 162, 35 (2012). CrossRef
    19. C.-T. Li, K.-C. Lo, H.-Y. Chang, H.-T. Wu, J. H. Ho and T.-J. Yen, Biosens. Bioelectron. 36, 192 (2012). CrossRef
    20. A. K. Sharma and B. D. Gupta, Opt. Commun. 245, 159 (2005). CrossRef
    21. K.-S. Lee, J. M. Son, D.-Y. Jeong, T. S. Lee and W. M. Kim, Sensors 10, 11390 (2010). CrossRef
    22. A. K. Sharma and B. D. Gupta, J. Appl. Phys. 101, 093111 (2007). CrossRef
    23. Y. Chen, R. S. Zheng, D. G. Zhang, Y. H. Lu, P. Wang, H. Ming, Z. F. Luo and Q. Kan, Appl. Opt. 50, 387 (2011). CrossRef
    24. S. H. Choi and K. M. Byun, J. Opt. Soc. Am. A 27, 2229 (2010). CrossRef
  • 作者单位:Yeon Kyung Lee (1)
    Young-Soo Sohn (1)
    Kyeong-Seok Lee (2)
    Won Mok Kim (2)
    Jeong-Ok Lim (3)

    1. Department of Biomedical Engineering, Catholic University of Daegu, Gyeonsan, 712-702, Korea
    2. Electronic Material Research Center, Korean Institute of Science and Technology, Seoul, 136-791, Korea
    3. Biomedical Research Institute, Kyungpook National University School of Medicine, Deagu, 700-721, Korea
  • ISSN:1976-8524
文摘
The characteristics of a waveguide-coupled bimetallic (WCBiM) chip for a surface plasmon resonance (SPR) sensor in a fixed-angle mode were investigated to verify sensitivity enhancement. The narrower full width at half maximum of the reflectivity curve of the WCBiM chip resulted in a dramatic change in reflectance. The configuration of the WCBiM chip consists of a multilayer stack of Ag/Zns-SiO2/Au. The SPR resolution of the WCBiM chip in the fixed mode was enhanced. At a concentration of 1 pg/ml of bovine serum albumin, the output response of the WCBiM chip was about four times larger than that of a Au chip.
NGLC 2004-2010.National Geological Library of China All Rights Reserved.
Add:29 Xueyuan Rd,Haidian District,Beijing,PRC. Mail Add: 8324 mailbox 100083
For exchange or info please contact us via email.