Using Ligasure?or Harmonic Ace? in Laparoscopic Sleeve Gastrectomies? A Prospective Randomized Study
详细信息    查看全文
  • 作者:Dimitrios Tsamis ; Maria Natoudi ; Aggeliki Arapaki ; Ioannis Flessas…
  • 关键词:Sleeve gastrectomy ; Ligasure?/li> Harmonic Ace? ; Laparoscopic instruments
  • 刊名:Obesity Surgery
  • 出版年:2015
  • 出版时间:August 2015
  • 年:2015
  • 卷:25
  • 期:8
  • 页码:1454-1457
  • 全文大小:140 KB
  • 参考文献:1.Rimonda R, Arezzo A, Garrone C, et al. Electrothermal bipolar vessel sealing system vs. harmonic scalpel in colorectal laparoscopic surgery: a prospective, randomized study. Dis Colon Rectum. 2009;52(4):657-1. doi:10.-007/?DCR.-b013e3181a0a70a-/span> .PubMed View Article
    2.Targarona EM, Balague C, Marin J, et al. Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis. Surg Innov. 2005;12(4):339-4.PubMed View Article
    3.Lopez J, Vilallonga R, Targarona EM, et al. Can LigaSure?be used to perform sleeve gastrectomy? - Tensile strength and histological changes. Minim Invasive Ther Allied Technol. 2013.
    4.Campagnacci R, de Sanctis A, Baldarelli M, et al. Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study. Surg Endosc. 2007;21(9):1526-1.PubMed View Article
    5.Deitel M, Crosby RD, Gagner M. The First International Consensus Summit for Sleeve Gastrectomy (SG), New York City, October 25-27, 2007. Obes Surg. 2008;18(5):487-6. doi:10.-007/?s11695-008-9471-5 .PubMed View Article
    6.D'Hondt M, Vanneste S, Pottel H, et al. Laparoscopic sleeve gastrectomy as a single-stage procedure for the treatment of morbid obesity and the resulting quality of life, resolution of comorbidities, food tolerance, and 6-year weight loss. Surg Endosc. 2011;25(8):2498-04. doi:10.-007/?s00464-011-1572-x .PubMed View Article
    7.Barrett WL, Garber SM. Surgical smoke: a review of the literature. Is this just a lot of hot air? Surg Endosc. 2003;17:979-7.PubMed View Article
    8.Harrell AG, Kercher KW, Heniford BT. Energy sources in laparoscopy. Semin Laparosc Surg. 2004;11:201-.PubMed
    9.Garas G, Okabayashi K, Ashrafian H, et al. Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies. Thyroid. 2013;23(9):1138-0. doi:10.-089/?thy.-012.-588 .PubMed View Article
    10.Rahbari R, Mathur A, Kitano M, et al. Prospective randomized trial of ligasure versus harmonic hemostasis technique in thyroidectomy. Ann Surg Oncol. 2011;18(4):1023-. doi:10.-245/?s10434-010-1251-5 .PubMed View Article
    11.Kwok SY, Chung CC, Tsui KK, et al. A double-blind, randomized trial comparing Ligasure and Harmonic Scalpel hemorrhoidectomy. Dis Colon Rectum. 2005;48(2):344-.PubMed View Article
    12.Miccoli P, Berti P, Dionigi GL, et al. Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg. 2006;132:1069-3.PubMed View Article
    13.Petrakis IE, Kogerakis NE, Lasithiotakis KG, et al. LigaSure versus clamp-and-tie thyroidectomy for benign nodular disease. Head Neck. 2004;26:903-.PubMed View Article
    14.Harold KL, Pollinger H, Matthews BD, et al. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc. 2003;17:1128-30.
    15.Heniford BT, Matthews BD, Sting RF, et al. Initial results with an electrothermal bipolar vessel sealer. Surg Endosc. 2001;15:799-01.PubMed View Article
    16.Takada M, Ichihara T, Kuroda Y. Comparative study of electrothermal bipolar vessel sealer and ultrasonic coagulating shears in laparoscopic colectomy. Surg Endosc. 2005;19:226-.PubMed View Article
  • 作者单位:Dimitrios Tsamis (1)
    Maria Natoudi (1)
    Aggeliki Arapaki (1)
    Ioannis Flessas (1)
    Ioanna Papailiou (1)
    Konstantinos Bramis (1)
    Georgios Zografos (1)
    Emmanouil Leandros (1)
    Konstantinos Albanopoulos (1)

    1. Endoscopic Surgery Department, ? Propaideutic Surgical Clinic of University of Athens, Hippokration Hospital, Vas. Sofias 114, Athens, 11527, Greece
  • 刊物主题:Surgery;
  • 出版者:Springer US
  • ISSN:1708-0428
文摘
Background Laparoscopic sleeve gastrectomy is one of the most recent advances of surgery for treating morbid obesity. Many laparoscopic devices have evolved to provide vascular control and tissue dissection. Methods This is a prospective randomized study comparing the intraoperative and postoperative complications and operative time of two groups of patients who underwent laparoscopic sleeve gastrectomy. In the first group after randomization, sleeve gastrectomy was performed using Ligasure?and in the second group Harmonic Ace? was used. Results In total, 94 patients were enrolled in the study allocated in two groups. In group 1, 43 patients were operated using Ligasure? and in group 2, 51 patients were operated using Harmonic Ace?. No significant differences were highlighted between these two groups with regards to operative time (45.0?±-5.0 vs 40.0?±-0.0?min, p--.199), intraoperative complications (32.6 vs 15.7?%, p--.054) and postoperative complications (4.7 vs 17.6?%, p--.051). Conclusions Both Ligasure?and Harmonic Ace? provide surgeons ergonomy, and no significant differences were shown in operative time and complications. Safety and efficacy in such demanding operations is of critical importance. Choice between these two shears lies with surgeon’s preference.