文摘
This paper focuses on improving the performance of the vertical open refrigerated display cabinets (VORDC) by optimizing the structure of deflector, which is affected by inlet velocity and velocity distribution of air curtains. The results show that the temperature of products located at the front and at the rear reduces as the increases of inlet velocity of air curtains. The increase of the inlet velocity of air curtains can strengthen the disturbance inside the VORDC, and also decrease the temperature of products inside the VORDC; the increase of the outer velocity of air curtain will exacerbate the disturbance outside the VORDC and decrease air curtain’s performance. The present study can provide a theoretical foundation for the design of VORDC.List of symbols\(a\)Absorption rate\(C_{\mu }\)Coefficient in K-\(\varepsilon\)\(G_{K}\)Generation of turbulence kinetic energy\({\rm I}\)Directional radiation intensityKTurbulence kinetic energySGeneralized source termTTemperature, [K or °C]uVelocity component in X-direction, velocity (m s−1)vVelocity component in Y-direction, velocity (m s−1)VVelocity vector