管道站场输油泵机组无功补偿节电效果分析
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:The Energy Saving Effect Analysis of Reactive Power Compensation for Oil Transfer Pump Units in Pipeline Station
  • 作者:蒲镇东 ; 刘国豪 ; 唐煌 ; 黄杉
  • 英文作者:PU Zhendong;LIU Guohao;TANG Huang;HUANG Shan;Western Branch of China Petroleum Pipeline Co.,LTD;
  • 关键词:输油泵机组 ; 无功功率补偿 ; 功率因数 ; 节电效果
  • 英文关键词:oil pump unit;;reactive power compensation;;power factor;;SVC;;SVG;;power saving effect
  • 中文刊名:GWYT
  • 英文刊名:Energy Conservation in Petroleum & Petrochemical Industry
  • 机构:中国石油管道有限责任公司西部分公司;中国石油管道公司管道科技研究中心;中国石油管道有限责任公司西部管道甘肃分公司;中国石油管道公司中原输油气分公司;
  • 出版日期:2018-07-31 13:14
  • 出版单位:石油石化节能
  • 年:2018
  • 期:v.8;No.89
  • 语种:中文;
  • 页:GWYT201807018
  • 页数:3
  • CN:07
  • ISSN:23-1572/TE
  • 分类号:10+48-49
摘要
输油泵电动机耗电是输油管道主要的耗能之一,如何在保证电动机满足生产要求的运行条件下,尽可能的提高用电效率,减少电能消耗是各级技术人员的目标。电动机加装就地无功功率补偿是节电措施之一,通过介绍无功功率补偿的原理和作用,选择某一输油站场1台输油泵电动机进行投用、不投用就地补偿装置2个状态下的电能数据对比分析,数据表明投用补偿装置后,电动机实际功率因数明显提高,在流量增加4.7%的情况下,无功功率减少58.68%,输入有功功率减少6.3%,电流下降17.44%,机组效率升高4.23%,各项主要参数在投用就地无功功率补偿后节电效果明显且机组效率提高。
        Oil pump motor power consumption is one of the main energy pipelines, how to ensure that the motor meets the production requirements of the operating conditions, as much as possible to improve electricity efficiency, reduce power consumption is the goal of all levels of technical staff. Motor installation of reactive power compensation is one of the energy-saving measures. By introducing the principle and role of reactive power compensation, we choose a oil pump motor make a contrast, observe separately two states of the power data comparison analysis. The data shows that after commissioning the compensation device, the actual power factor of the motor is obviously improved. In the case of a 4.7% increase in flow, the reactive power is reduced by58.68%, the input active power is reduced by 6.3%, the current is decreased by 17.44%, and the unit efficiency is increased by 4.23%. The main parameters have obvious power saving effect after the local reactive power compensation is applied and the unit efficiency is improved. A comparison was made between the SVC capacitance compensation device and the new SVG compensation device in the pipeline station. Propose the next step how to use the analysis of reactive power compensation in pipeline station. Finally achieve the goal of helping energy saving.
引文
[1]刘国豪,张帅,施若斯,等.长输原油管道主要耗能设备节能测试与分析[J].石油石化节能,2013,29(3):10-11.
    [2]国家质量监督检验检疫总局.三相异步电动机经济运行:GB/T 12497─2006[S].北京:中国标准出版社,2006:3-6.
    [3]国家质量监督检验检疫总局.泵类液体输送系统节能监测:GB/T 16666─2012[S].北京:中国标准出版社,2013:3-5.
    [4]国家能源局.石油企业用节能产品节能效果测定:SY/T 6422─2016[S].北京:石油工业出版社,2016:4-5.
    [5]刘国豪,管维均,张旭东,等.十一五油气输送管道系统能耗设备节能监测情况分析[J].油气储运,2013,32(11):1202-1205.
    [6]国家能源局.油气输送管道系统节能监测规范:SY/T 6837─2011[S].北京:石油工业出版社,2011:4-6.